The sealing effect and degradation of polydioxanone weaving tracheal stents in a canine airway defect model
Open Access
- 23 October 2025
- journal article
- Published by IOP Publishing in Biomedical Materials
- Vol. 20 (6) , 065014
Abstract
The use of covered self-expandable metal (CSEM) stents for fistulas sealing is a common clinical approach. However, these stents need to be removed once their therapeutic goals are achieved. Our study designed and fabricated a dumbbell-shaped, high-porosity, biodegradable polydioxanone weaving tracheal (PW) stent, and investigated its sealing efficacy and degradation characteristics. A tracheal defect model was created in 24 beagle dogs. Six dogs were implanted with CSEM stents, while the remaining 18 dogs received PW stents. The dogs in the CSEM and PW groups were observed for up to 8 and 14 weeks, respectively, with clinical symptoms, tracheoscopy, computed tomography scans, and fluoroscopy monitored. Subsequently, the stents were retrieved to observe morphological changes, and measure mechanical properties. The PW stents exhibited excellent airtightness, with significantly fewer complications such as stent displacement and granulation tissue hyperplasia compared to the CSEM stents. The tracheal tissue response to the PW stent was relatively mild. After PW stent implantation, collagen fiber deposition at the defect site gradually increased, and cartilage structure regeneration was observed in later stages. Notably, cilia were largely absent in the tracheal epithelium, with squamous metaplasia observed even in the later stages of the experiment following PW stent implantation. Additionally, the PW stents remained mostly intact in the canine airways until week 12, and were completely degraded and disappeared from the canine airways at week 14, without causing severe complications. The PW stent, featuring excellent biocompatibility and uniform degradation in the large-animal airway, demonstrated clinical effectiveness in sealing tracheal defects.Keywords
Funding Information
- National Natural Science Foundation Project (81970093)
This publication has 49 references indexed in Scilit:
- Further experience with polydioxanone airway stents in childrenPediatric Pulmonology, 2024
- Pivotal trial of a biodegradable stent for patients with refractory benign esophageal strictureEsophagus, 2022
- Stent traqueal biodegradable de polidioxanona. Estudio de la reactividad en conejoArchivos de Bronconeumología, 2020
- The 2010s in clinical drug-eluting stent and bioresorbable scaffold research: a Dutch perspectiveNetherlands Heart Journal, 2020
- In vitro degradation and biocompatibility evaluation of typical biodegradable metals (Mg/Zn/Fe) for the application of tracheobronchial stenosisBioactive Materials, 2019
- Characterization of the biomechanical properties of canine trachea using a customized 3D-printed apparatusAuris Nasus Larynx, 2019
- Initial experience with a new biodegradable airway stent in children: Is this the stent we were waiting for?Pediatric Pulmonology, 2015
- Agent-based modeling of porous scaffold degradation and vascularization: Optimal scaffold design based on architecture and degradation dynamicsActa Biomaterialia, 2015
- Complications of Silicone Stent Insertion in Patients With Expiratory Central Airway CollapseThe Annals of Thoracic Surgery, 2007
- Mechanical properties and in vitro degradation of bioresorbable fibers and expandable fiber‐based stentsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005