Estimation and filtering of physiological tremor for real‐time compensation in surgical robotics applications
Authors:
- 26 August 2010
- journal article
- research article
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 6 (3) , 334-342
Abstract
Background: Physiological tremor is the main cause of imprecision in microsurgical procedures/robotics applications. Existing methods, such as weighted‐frequency Fourier linear combiner (WFLC), rely on estimating the tremor under the assumption that it has a single dominant frequency. This paper focuses on developing a new algorithm for accurate tremor filtering in real time.Methods: A study conducted on several novice subjects and microsurgeons showed the tremor to contain several dominant frequencies in a band, rather than a single dominant frequency. Based on the tremor characteristics, a new algorithm band‐limited multiple Fourier linear combiner (BMFLC) has been developed to estimate a band of signals with multiple dominant frequencies. A separation procedure to separate the intended motion/drift from the tremor portion is also discussed.Results: A simulation study was first conducted to validate the theoretical development on recorded tremor data. The experimental set‐up was designed to study the real‐time performance of the proposed algorithm. Tremor sensing using accelerometers is also discussed, with the proposed algorithm. Our experiments showed that the developed BMFLC algorithm had an average tremor compensation of 64% compared to 43% for the WFLC algorithm in real‐time for one degree of freedom (1‐DOF) cancellation of tremor.Conclusions: The BMFLC algorithm can be applied for the three axes separately and 3‐DOF cancellation of tremor can be achieved. Further research is required to deal with complex gestures involved during microsurgery. Copyright © 2010 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Robotic Compensation of Biological Motion to Enhance Surgical AccuracyProceedings of the IEEE, 2006
- Optimal digital filtering for tremor suppressionIEEE Transactions on Biomedical Engineering, 2000
- Modeling Noisy Time Series: Physiological TremorInternational Journal of Bifurcation and Chaos, 1998
- Adaptive cancelling of physiological tremor for improved precision in microsurgeryIEEE Transactions on Biomedical Engineering, 1998
- Adaptive algorithms for the rejection of sinusoidal disturbances with unknown frequencyAutomatica, 1997
- Quantitative Measurement of the Effects of Caffeine and Propranolol on Surgeon Hand TremorArchives of Ophthalmology (1950), 1997
- Modeling and canceling tremor in human-machine interfacesIEEE Engineering in Medicine and Biology Magazine, 1996
- An adaptive estimation of periodic signals using a Fourier linear combinerIEEE Transactions on Signal Processing, 1994
- Adaptive Fourier estimation of time-varying evoked potentialsIEEE Transactions on Biomedical Engineering, 1989
- Physiologic tremor and microsurgeryMicrosurgery, 1983