A2, M2, P2 aneurysms and beyond: results of treatment with pipeline embolization device in 65 patients
- 23 January 2019
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 11 (9) , 903-907
Abstract
Background Intracranial aneurysms located in the distal vessels are rare and remain a challenge to treat through surgical or endovascular interventions. Objective To describe a multicenter approach with flow diversion using the pipeline embolization device (PED) for treatment of distal intracranial aneurysms. Methods Cases of distal intracranial aneurysms defined as starting on or beyond the A2 anterior cerebral artery, M2 middle cerebral artery, and P2 posterior cerebral artery segments were included in the final analysis. Results 65 patients with distal aneurysms treated with the PED were analyzed. Median aneurysm size at the largest diameter was 7.0 mm, 60% were of a saccular morphology, and 9/65 (13.8%) patients presented in the setting of acute rupture. Angiographic follow-up data were available for 53 patients, with a median follow-up time of 6 months: 44/53 (83%) aneurysms showed complete obliteration, 7/53 (13.2%) showed reduced filling, and 2/53 (3%) showed persistent filling. There was no association between patient characteristics, including aneurysm size (P=0.36), parent vessel diameter (P=0.27), location (P=0.81), morphology (P=0.63), ruptured status on admission (P=0.57), or evidence of angiographic occlusion at the end of the embolization procedure (P=0.49). Clinical outcome data were available for 60/65 patients: 95% (57/60) had good clinical outcome (modified Rankin Scale score of 0–2) at 3 months. Conclusions This large multicenter study of patients with A2, M2, and P2 distal aneurysms treated with the PED showed that flow diversion may be an effective treatment approach for this rare type of vascular pathology. The procedural compilation rate of 7.7% indicates the need for further studies as the flow diversion technology constantly evolves.Keywords
This publication has 13 references indexed in Scilit:
- Endovascular Treatment of Complex Distal Posterior Cerebral Artery Aneurysms with the Pipeline Embolization DeviceWorld Neurosurgery, 2017
- Pipeline Embolization Device for Pericallosal Artery Aneurysms: A Retrospective Single Center Safety and Efficacy StudyOperative Neurosurgery, 2017
- Update on flow diverters for the endovascular management of cerebral aneurysmsNeurosurgical Focus, 2017
- Tourniquet parent artery occlusion after flow diversionJournal of NeuroInterventional Surgery, 2017
- Treatment of complex anterior cerebral artery aneurysms with Pipeline flow diversion: mid-term resultsJournal of NeuroInterventional Surgery, 2016
- Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization DeviceNeurosurgery, 2016
- Pipeline endovascular device for the treatment of intracranial aneurysms at the level of the circle of Willis and beyond: multicenter experienceJournal of NeuroInterventional Surgery, 2014
- Flow diversion for complex middle cerebral artery aneurysmsNeuroradiology, 2014
- Distal Aneurysms of Intracranial Arteries: Application of Numerical Nomenclature, Predilection for Cerebellar Arteries, and Results of Surgical ManagementWorld Neurosurgery, 2013
- Endovascular treatment of proximal and distal posterior inferior cerebellar artery aneurysmsJournal of Neurosurgery, 2013