Psychological Adjustment in ICD Patients Living With Advisory Fidelis Leads
Authors:
- Samuel F. SearsSSSamuel F. Sears
- Jordan ShawJSJordan Shaw
- Michael H. GollobMGMichael H. Gollob
- Barbara AmyotteBABarbara Amyotte
- David H. BirnieDBDavid H. Birnie
- 19 August 2010
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (1) , 57-63
Abstract
Psychological Adjustment and Fidelis ICD Leads. Introduction: Implantable cardioverter defibrillators (ICD) advisory notices present treatment dilemmas for physicians and patients. On one side, the risk of device malfunction and the likely severity of clinical sequelae have to be estimated. This estimate has to be weighed against the risks of surgery to replace the advisory component. It is unclear whether there is important psychological morbidity associated with living with an ICD under advisory and whether this should be factored into decision making. The study had 2 objectives: (1) to examine whether there is adverse psychological adjustment when an ICD is under advisory, and (2) to assess the psychological sequel of advisory ICD component malfunction. Methods: This study focused on the Sprint Fidelis advisory. All patients in our practice who still had an in service Medtronic Fidelis lead were included in the study. Three groups were compared: advisory group but no fracture (n = 249), advisory group with lead fracture (n = 24), and a control group (n = 143). For both objectives, we used a general anxiety and depression instrument and also device-specific measures of psychological well being. Results and Conclusions: First, there was no evidence of differences in the psychological functioning of patients at risk of ICD lead malfunction compared to a control group. Second, patients who had experienced an ICD lead fracture had adverse psychological morbidity compared to control patients, and this appeared, primarily, to be related to receiving inappropriate shock(s) at the time of the fracture. (J Cardiovasc Electrophysiol, Vol. 22, pp. 57-63, January 2011)Keywords
This publication has 29 references indexed in Scilit:
- The Psychological Impact of Implantable Cardioverter‐Defibrillator Recalls and the Durable Positive Effects of CounselingPacing and Clinical Electrophysiology, 2009
- A Viewpoint on the Impact of Device Advisories on Patient‐Centered OutcomesPacing and Clinical Electrophysiology, 2009
- How to Respond to an Implantable Cardioverter-Defibrillator RecallCirculation, 2009
- Impact of Implantable Cardioverter‐Defibrillator Recalls on Patients' Anxiety, Depression, and Quality of LifePacing and Clinical Electrophysiology, 2008
- Quality of Life with Defibrillator Therapy or Amiodarone in Heart FailureNew England Journal of Medicine, 2008
- Correlates of Patient Acceptance of the Cardioverter Defibrillator: Cross‐Validation of the Florida Patient Acceptance Survey in Danish PatientsPacing and Clinical Electrophysiology, 2008
- Decision-making, emotional distress, and quality of life in patients affected by the recall of their implantable cardioverter defibrillatorEP Europace, 2008
- Quality of Life Among Implantable Cardioverter‐Defibrillator Recipients in the Primary Prevention Therapeutic EraPacing and Clinical Electrophysiology, 2007
- Measurement of Patient Fears About Implantable Cardioverter Defibrillator Shock: An Initial Evaluation of the Florida Shock Anxiety ScalePacing and Clinical Electrophysiology, 2006
- The Hospital Anxiety and Depression ScaleActa Psychiatrica Scandinavica, 1983