Influence of Background Voltage Distortion on Operation of Passive Harmonic Compensation Devices
Open Access
Abstract
This paper discusses the issues of assessing the influence of external distortion sources on the functioning of a shunt passive harmonic filter. In this study, we evaluated the overload of a passive harmonic filter based on determining the contributions of distortion sources. A method was proposed for assessing the contributions of distortion sources, which allowed us, regardless of background distortions, to determine the contributions of consumer loads, as well as the contribution of background distortions. The simulation was carried out using the Simulink MatLab software (version R2023a). Several scenarios were considered in which the following values were varied: supply feeder impedance, level of background distortions, consumer electrical load composition, and passive filter parameters. It was found that the contribution of the background distortion source decreases with increasing impedance of the supply grid. It was determined that the consumer load contribution is independent of background voltage harmonics and can be used to estimate the overload of a passive harmonic filter. It was shown that it is necessary to take into account the overload of the passive filter by currents from background distortion sources, which did not exceed 135% of the rated rms current for the conditions under consideration. A mathematical model was proposed to estimate the overload of a passive filter in the presence of background voltage distortions. This model was obtained during analytical studies and allows one to evaluate the overload of a passive filter, taking into account the short circuit ratio, detuning frequency and power of the passive filter, and the share contribution of background distortion sources.Keywords
Funding Information
- Russian Science Foundation (21-79-10027)
This publication has 39 references indexed in Scilit:
- Hybrid system of hydrogen generation by water electrolysis and methane partial oxidationInternational Journal of Hydrogen Energy, 2023
- Impact of distributed energy resources on power quality: Brazilian scenario analysisElectric Power Systems Research, 2022
- Design and application of a single‐tuned passive harmonic filter to suppress harmonic distortion and resonance for railway traction power systems—A case studyIET Electrical Systems in Transportation, 2021
- Revisiting the active power direction methodIET Generation, Transmission & Distribution, 2021
- Application of mixed integer distributed ant colony optimization to the design of undamped single-tuned passive filters based harmonics mitigationSwarm and Evolutionary Computation, 2019
- Comparative evaluation of common passive filter types regarding maximization of transformer’s loading capability under non-sinusoidal conditionsElectric Power Systems Research, 2018
- Optimal Sizing ofC-Type Passive Filters under Non-Sinusoidal ConditionsEnergy Technology & Policy, 2014
- Harmonic emission limits and responsibilities at a point of connectionIET Generation, Transmission & Distribution, 2012
- Optimal sizing and limitations of passive filters in the presence of background harmonic distortionElectrical Engineering, 2009
- A hybrid active filter for damping of harmonic resonance in industrial power systemsIEEE Transactions on Power Electronics, 2000