On the use of fluxmetric methods for characterizing feebly magnetic materials
- 1 May 2017
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
The problems related to the use of a split-coil permeameter for measuring the magnetic properties of materials with low relative permeability are faced. In particular, a challenging problem arises from the series production of steel tapes: magnetic and paramagnetic materials, in fact, exhibit different magnetic properties according to the production process (i.e. annealing and cold work). Consequently, samples of this material differently treated have to be characterized in order to find the optimal cold work and annealing able to minimize raising of magnetism. In this paper, fluxmetric methods, widely employed for magnets testing, are extended to the characterization of feebly magnetic materials. A case study for the series production of steel tapes about co-wound 1.430 stainless steel tapes, the material used for the quench detection in ITER TF coils [1], is presented.Keywords
This publication has 6 references indexed in Scilit:
- A software framework for developing measurement applications under variable requirementsReview of Scientific Instruments, 2012
- Measurements of magnetic materialsMetrologia, 2010
- Design and Specifications of the ITER TF CoilsIEEE Transactions on Applied Superconductivity, 2008
- A vertical force alternating-gradient magnetometerReview of Scientific Instruments, 1990
- A Faraday Type Magnetometer with an Adjustable Field Independent GradientReview of Scientific Instruments, 1971
- Versatile and Sensitive Vibrating-Sample MagnetometerReview of Scientific Instruments, 1959