Anisotropic analysis of multi‐component T2 and T1ρ relaxations in achilles tendon by NMR spectroscopy and microscopic MRI
Open Access
- 24 January 2013
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (3) , 625-633
Abstract
Purpose: To study the anisotropic characteristics of both multi‐component T2 and T1ρ relaxation times in tendon.Materials and Methods: T2 and T1ρ were measured in tendon by NMR spectroscopy at different orientations and by microscopic MRI at the magic angle. Several experimental issues in the multi‐component relaxation measurements were investigated, including the effects of echo spacing, the resolution of MRI experiments, the influence of the specimen orientations, and the strengths of different spin‐lock frequencies in T1ρ experiments.Results: Both the values and fractions of T2 in tendon showed significant orientational dependence. The values and fractions of T1ρ strongly depended on both the specimen orientation and the spin‐lock strength. The imaging resolution (35–280 μm) had little influence in the T2 experiments. Both the echo spacings (0.6–3.0 ms) in the T2 experiment and the spin‐lock strengths (0.5–5 kHz) in the T1ρ experiment affected the quantification of the multi‐component relaxation. Up to three T2 and T1ρ components were resolved in tendon.Conclusion: Multi‐component relaxations could be attributed to different populations of water in the tissue. The transitions between a mono‐component and multi‐component result call for the caution in interpreting the relaxation results. J. Magn. Reson. Imaging 2013;38:625–633. © 2013 Wiley Periodicals, Inc.Keywords
This publication has 37 references indexed in Scilit:
- Dependencies of multi-component T2 and T1ρ relaxation on the anisotropy of collagen fibrils in bovine nasal cartilageJournal of Magnetic Resonance, 2011
- Improved specificity of cartilage matrix evaluation using multiexponential transverse relaxation analysis applied to pathomimetically degraded cartilageNMR in Biomedicine, 2011
- On the measurement of multi-component T2 relaxation in cartilage by MR spectroscopy and imagingMagnetic Resonance Imaging, 2010
- Multi-components of T2 relaxation in ex vivo cartilage and tendonJournal of Magnetic Resonance, 2009
- In vivo T1ρ and T2 mapping of articular cartilage in osteoarthritis of the knee using 3 T MRIOsteoarthritis and Cartilage, 2007
- Study of order and dynamic processes in tendon by NMR and MRIJournal of Magnetic Resonance Imaging, 2007
- Anisotropy of collagen fiber orientation in sheep tendon by 1H double-quantum-filtered NMR signalsJournal of Magnetic Resonance, 2003
- Origin of cartilage laminae in MRIJournal of Magnetic Resonance Imaging, 1997
- Quantitative interpretation of NMR relaxation dataJournal of Magnetic Resonance (1969), 1989
- Variation in measured transverse relaxation in tissue resulting from spin locking with the CPMG sequenceJournal of Magnetic Resonance (1969), 1988