Outcome of Repair of Distal Radial and Ulnar Fractures in Dogs Weighing 4 kg or Less Using a 1.5-mm Locking Adaption Plate or 2.0-mm Limited Contact Dynamic Compression Plate
- 1 November 2017
- journal article
- research article
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 30 (6) , 444-452
Abstract
Objectives Retrospective evaluation of repairing distal radial and ulnar fractures in small breed dogs with the Synthes 1.5-mm locking Adaption plate system and compare results in a similar group of patients repaired with the Synthes 2.0-mm limited contact-dynamic compression plate (LC-DCP). Methods Electronic medical records from one specialty referral centre were reviewed from March 21, 2010, to October 9, 2015, for patients weighing less than or equal to 4 kg that had a distal one-third radial and ulnar fracture repaired with a Synthes 1.5-mm locking adaption plate or Synthes 2.0-mm LC-DCP. Further inclusion criteria included application of the plate to the cranial surface of the radius via open reduction and internal fixation. Results Six 1.5-mm Adaption plates and 7 2.0-mm LC-DCPs were used to repair 13 distal radial and ulnar fractures in 12 dogs. There were three major complications in the 1.5-mm adaption plate group (one plate fracture, one screw pull-out and one fracture through a distal screw hole) and one major complication in the 2.0-mm LC-DCP group due to a re-fracture. All patients without a complication had good or excellent functional outcome. Clinical Significance The authors recommend that the 1.5-mm Adaption plate be used only when a 2.0-mm LC-DCP would not allow for a minimum of two screws in the distal segment and at the discretion of the surgeon.Keywords
This publication has 9 references indexed in Scilit:
- Open reduction and cranial bone plate fixation of fractures involving the distal aspect of the radius and ulna in miniature- and toy-breed dogs: 102 cases (2008–2015)Journal of the American Veterinary Medical Association, 2017
- Conventional bone plate fixation of distal radius and ulna fractures in toy breed dogsAustralian Veterinary Journal, 2016
- Locking compression plate stabilization of 20 distal radial and ulnar fractures in toy and miniature breed dogsVeterinary and Comparative Orthopaedics and Traumatology, 2015
- Retrospective Comparison of Minimally Invasive Plate Osteosynthesis and Open Reduction and Internal Fixation of Radius‐Ulna Fractures in DogsVeterinary Surgery, 2012
- The concept of locking platesOrthopaedics & Traumatology: Surgery & Research, 2010
- Cross-sectional geometrical properties of distal radius and ulna in large, medium and toy breed dogsJournal of Biomechanics, 2006
- General principles for the clinical use of the LCPInjury, 2003
- Bone plate fixation of distal radius and ulna fractures in small- and miniature-breed dogsJournal of the American Animal Hospital Association, 1999
- The Intraosseous Blood Supply of the Canine Radius: Implications for Healing of Distal Fractures in Small DogsVeterinary Surgery, 1997