Separation of dsDNA in the presence of electroosmotic flow under discontinuous conditions
- 18 July 2001
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 22 (11) , 2281-2290
Abstract
Separations of φX‐174/HaeIII DNA restriction fragments have been performed in the presence of electroosmotic flow (EOF) using five different polymer solutions, including linear polyacrylamide (LPA), poly(ethylene oxide) (PEO), hydroxypropylcellulose (HPC), hydroxyethylcellulose (HEC), and agarose. During the separation, polymer solutions entered the capillary by EOF. When using LPA solutions, bulk EOF is small due to adsorption on the capillary wall. On the other hand, separation is faster and better for the large DNA fragments (> 872 base pairs, bp) using derivative celluloses and PEO solutions. Several approaches to optimum resolution and speed by controlling EOF and/or altering electrophoretic mobility of DNA have been developed, including (i) stepwise changes of ethidium bromide (0.5–5 µg/mL), (ii) voltage programming (125–375 V/cm), (iii) use of mixed polymer solutions, and (iv) use of high concentrations of Tris‐borate (TB) buffers. The DNA fragments ranging from 434 to 653 bp that were not separated using 2% PEO (8 000 000) under isocratic conditions have been completely resolved by either stepwise changes of ethidium bromide or voltage programming. Compared to PEO solutions, mixed polymer solutions prepared from PEO and HEC provide higher resolving power. Using a capillary filled with 600 mM TB buffers, pH 10.0, high‐speed (< 15 min) separation of DNA (pBR 322/HaeIII digest, pBR 328/BglI digest and pBR 328/HinfI digest) has been achieved in 1.5% PEO.Keywords
This publication has 40 references indexed in Scilit:
- Gel electrophoretic mobility of single-stranded DNA: The two reptation field-dependent factorsElectrophoresis, 2000
- Capillary electrophoresis in sieving matrices: Selectivity per base, mobility slope, and inflection slopeElectrophoresis, 1999
- Capillary Modification by Noncovalent Polycation Adsorption: Effects of Polymer Molecular Weight and Adsorption Ionic StrengthAnalytical Chemistry, 1999
- High-Efficiency DNA Separation by Capillary Electrophoresis in a Polymer Solution with Ultralow ViscosityAnalytical Chemistry, 1999
- Capillary electrophoretic separation of 1 to 10 kbp sized dsDNA using poly(ethylene oxide) solutions in the presence of electroosmotic counterflowElectrophoresis, 1998
- Electrostatic and Hydrodynamic Separation of DNA Fragments in Capillary TubesAnalytical Chemistry, 1996
- Activation energy of the separation of DNA sequencing fragments in denaturing noncross‐linked polyacrylamide by capillary elecrophoresisElectrophoresis, 1996
- The effects of polymer properties on DNA separations by capillary electrophoresis in uncross‐linked polymer solutionsElectrophoresis, 1996
- DNA shape and separation efficiency in polymer media: A computerized method based on electrophoretic mobility dataElectrophoresis, 1993
- Experimental and theoretical studies of DNA separations by capillary electrophoresis in entangled polymer solutionsBiopolymers, 1991