Abstract
Aim: To map the glycaemic variabilities and insulin requirements across different phases of the menstrual cycle and assess the efficacy and performance of the MiniMed 780G system on mitigating glycaemic variabilities during phases of the menstrual cycle. Materials and Methods: A pilot study recruiting 15 adolescent and young adult females with type 1 diabetes was conducted. Only females with regular spontaneous menstruation were enrolled in the current study. Phases of each menstrual cycle were determined as either follicular phase or luteal phase. The study analysed continuous glucose monitoring metrics during two study periods: the open loop period (OLP) and the advanced hybrid closed‐loop (AHCL) period; each period lasted 3 consecutive months. Results: During the OLP, the mean time in range (TIR) significantly decreased during the luteal phase compared with the follicular phase (65.13% ± 3.07% vs. 70.73% ± 2.05%) ( P < .01). The mean time above range significantly increased from 21.07% ± 2.58% during the follicular phase to 24.87% ± 2.97% during the luteal phase ( P < .01). After initiating the AHCL period, TIR was comparable during both phases of the menstrual cycle ( P = .72), without increasing the time spent below 70 mg/dL ( P > .05). Regarding insulin delivery during the AHCL period, the percentage of Auto basal and Auto correction delivered by the algorithm increased by 13.55% and 30.6%, respectively ( P < .01), during the luteal phase. Conclusions: The fully automated adaptive algorithm of the MiniMed 780G system mitigated menstrual cycle‐dependent glycaemic variability, successfully attaining the recommended glycaemic outcomes with a TIR greater than 70% throughout the entire menstrual cycle.Keywords
This publication has 24 references indexed in Scilit:
- Insulin Delivery and Glucose Variability Throughout the Menstrual Cycle on Closed Loop Control for Women with Type 1 DiabetesDiabetes Technology & Therapeutics, 2022
- Committee Opinion No. 651Obstetrics & Gynecology, 2015
- Menstrual cycle irregularities and their relationship with HbA1c and insulin dose in adolescents with type 1 diabetes mellitusFertility and Sterility, 2010
- Menstrual Cycle Effects on Insulin Sensitivity in Women with Type 1 Diabetes: A Pilot StudyDiabetes Technology & Therapeutics, 2007
- Cyclic Changes in Glycemia Assessed by Continuous Glucose Monitoring System During Multiple Complete Menstrual Cycles in Women with Type 1 DiabetesDiabetes Technology & Therapeutics, 2004
- Progesterone receptor knockout mice have an improved glucose homeostasis secondary to β-cell proliferationProceedings of the National Academy of Sciences, 2002
- Self-reported Changes in Capillary Glucose and Insulin Requirements During the Menstrual CycleDiabetic Medicine, 1996
- Effect of the menstrual cycle on energy and nutrient intakeThe American Journal of Clinical Nutrition, 1994
- Effect of the Menstrual Cycle on Glucose Metabolism and Diabetes Control in Women with Insulin-Dependent Diabetes MellitusSeminars in Reproductive Medicine, 1994
- Effect of Phase of Menstrual Cycle on Insulin Sensitivity, Peripheral Blood Flow and Cardiovascular Responses to Hyperinsulinaemia in Young Women with Type 1 DiabetesDiabetic Medicine, 1990