Errors in patient specimen collection: application of statistical process control
Authors:
- Walter Sunny DzikWDWalter Sunny Dzik
- Neil BeckmanNBNeil Beckman
- Kathleen SellengKSKathleen Selleng
- Nancy HeddleNHNancy Heddle
- Zbigniew SzczepiorkowskiZSZbigniew Szczepiorkowski
- Silvano WendelSWSilvano Wendel
- Michael MurphyMMMichael Murphy
- 1 October 2008
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 48 (10) , 2143-2151
Abstract
BACKGROUND: Errors in the collection and labeling of blood samples for pretransfusion testing increase the risk of transfusion-associated patient morbidity and mortality. Statistical process control (SPC) is a recognized method to monitor the performance of a critical process. An easy-to-use SPC method was tested to determine its feasibility as a tool for monitoring quality in transfusion medicine. STUDY DESIGN AND METHODS: SPC control charts were adapted to a spreadsheet presentation. Data tabulating the frequency of mislabeled and miscollected blood samples from 10 hospitals in five countries from 2004 to 2006 were used to demonstrate the method. Control charts were produced to monitor process stability. RESULTS: The participating hospitals found the SPC spreadsheet very suitable to monitor the performance of the sample labeling and collection and applied SPC charts to suit their specific needs. One hospital monitored subcategories of sample error in detail. A large hospital monitored the number of wrong-blood-in-tube (WBIT) events. Four smaller-sized facilities, each following the same policy for sample collection, combined their data on WBIT samples into a single control chart. One hospital used the control chart to monitor the effect of an educational intervention. CONCLUSION: A simple SPC method is described that can monitor the process of sample collection and labeling in any hospital. SPC could be applied to other critical steps in the transfusion processes as a tool for biovigilance and could be used to develop regional or national performance standards for pretransfusion sample collection. A link is provided to download the spreadsheet for freeKeywords
This publication has 10 references indexed in Scilit:
- Blood pack fault monitoringVox Sanguinis, 2004
- Current performance of patient sample collection in the UKTransfusion Medicine, 2004
- Review of the quality monitoring methods used by countries using or implementing universal leukoreductionTransfusion Medicine Reviews, 2004
- Emily Cooley Lecture 2002: transfusion safety in the hospitalTransfusion, 2003
- An international study of the performance of sample collection from patientsVox Sanguinis, 2003
- Value of central analysis of leucocyte depletion quality control data within the National Blood Service, EnglandVox Sanguinis, 2002
- Adherence to a strict specimen‐labeling policy decreases the incidence of erroneous blood grouping of blood bank specimensTransfusion, 1997
- Practical guidelines for process validation and process control of white cell‐reduced blood components: report of the Biomedical Excellence for Safer Transfusion (BEST) Working Party of the International Society of Blood Transfusion (ISBT)Transfusion, 1996
- A report of 104 transfusion errors in New York StateTransfusion, 1992
- The use of Control Charts in the Clinical Laboratory*American Journal of Clinical Pathology, 1950