Adaptive Models for Multi-Covariate Imaging of Sub-Resolution Targets (MIST)
- 30 June 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (7) , 2303-2317
Abstract
Multi-covariate imaging of sub-resolution targets (MIST) is a statistical, model-based image formation technique that smooths speckles and reduces clutter. MIST decomposes the measured covariance of the element signals into modeled contributions from mainlobe, sidelobes, and noise. MIST covariance models are derived from the well-known autocorrelation relationship between transmit apodization and backscatter covariance. During in vivo imaging, the effective transmit aperture often deviates from the applied apodization due to nonlinear propagation and wavefront aberration. Previously, the backscatter correlation length provided a first-order measure of these patient-specific effects. In this work, we generalize and extend this approach by developing data-adaptive covariance estimation, parameterization, and model-formation techniques. We performed MIST imaging using these adaptive models and evaluated the performance gains using 152 tissue-harmonic scans of fetal targets acquired from 15 healthy pregnant subjects. Compared to standard MIST imaging, the contrast-to-noise ratio (CNR) is improved by a median of 8.3%, and the speckle signal-to-noise ratio (SNR) is improved by a median of 9.7%. The median CNR and SNR gains over B-mode are improved from 29.4% to 40.4% and 24.7% to 38.3%, respectively. We present a versatile empirical function that can parameterize an arbitrary speckle covariance and estimate the effective coherent aperture size and higher order coherence loss. We studied the performance of the proposed methods as a function of input parameters. The implications of system-independent MIST implementation are discussed.Keywords
Funding Information
- National Institute of Health (R01-EB017711)
- National Institute of Health (R01-CA211602)
This publication has 39 references indexed in Scilit:
- The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical ImagingIEEE Transactions on Medical Imaging, 2014
- Reverberation Clutter from Subcutaneous Tissue Layers: Simulation and in Vivo DemonstrationsUltrasound in Medicine & Biology, 2014
- Short-lag spatial coherence of backscattered echoes: imaging characteristicsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2011
- Lesion Detectability in Diagnostic Ultrasound with Short-Lag Spatial Coherence ImagingUltrasonic Imaging, 2011
- Speckle coherence and implications for adaptive imagingThe Journal of the Acoustical Society of America, 1997
- Adaptive focusing in scattering media through sound-speed inhomogeneities: The van Cittert Zernike approach and focusing criterionThe Journal of the Acoustical Society of America, 1994
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991
- Reconstruction of a complex-valued object from the modulus of its Fourier transform using a support constraintJournal of the Optical Society of America A, 1987
- Phase retrieval algorithms: a comparisonApplied Optics, 1982
- Reconstruction of an object from the modulus of its Fourier transformOptics Letters, 1978