High-Resolution CT Imaging of the Temporal Bone: A Cadaveric Specimen Study
Authors:
- 31 January 2022
- journal article
- research article
- Published by Georg Thieme Verlag KG in Journal of Neurological Surgery Part B: Skull Base
- Vol. 83 (05) , 470-475
Abstract
Objective Super-high and ultra-high spatial resolution computed tomography (CT) imaging can be advantageous for detecting temporal bone pathology and guiding treatment strategies. Methods Six temporal bone cadaveric specimens were used to evaluate the temporal bone microanatomic structures utilizing the following CT reconstruction modes: normal resolution (NR, 0.5-mm slice thickness, 5122 matrix), high resolution (HR, 0.5-mm slice thickness, 1,0242 matrix), super-high resolution (SHR, 0.25-mm slice thickness, 1,0242 matrix), and ultra-high resolution (UHR, 0.25-mm slice thickness, 2,0482 matrix). Noise and signal-to-noise ratio (SNR) for bone and air were measured at each reconstruction mode. Two observers assessed visualization of seven small anatomic structures using a 4-point scale at each reconstruction mode. Results Noise was significantly higher and SNR significantly lower with increases in spatial resolution (NR, HR, and SHR). There was no statistical difference between SHR and UHR imaging with regard to noise and SNR. There was significantly improved visibility of all temporal bone osseous structures of interest with SHR and UHR imaging relative to NR imaging (p < 0.001) and most of the temporal bone osseous structures relative to HR imaging. There was no statistical difference in the subjective image quality between SHR and UHR imaging of the temporal bone (p ≥ 0.085). Conclusion Super-high-resolution and ultra-high-resolution CT imaging results in significant improvement in image quality compared with normal-resolution and high-resolution CT imaging of the temporal bone. This preliminary study also demonstrates equivalency between super-high and ultra-high spatial resolution temporal bone CT imaging protocols for clinical use. Received: 19 January 2021 Accepted: 12 November 2021 Publication Date: 31 January 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, GermanyKeywords
This publication has 33 references indexed in Scilit:
- Review of congenital inner ear abnormalities on CT temporal boneBritish Journal of Radiology, 2011
- Contributing Factors in the Pathogenesis of Acquired Cholesteatoma: Size Analysis Based on MDCTAmerican Journal of Roentgenology, 2011
- Assessing Stapes Piston Position Using Computed TomographyOtology & Neurotology, 2009
- Flat-Panel Volume CT: Fundamental Principles, Technology, and ApplicationsRadioGraphics, 2008
- Imaging Procedures After Bone‐Anchored Hearing Aid ImplantationThe Laryngoscope, 2007
- Role of 3D CT in the Evaluation of the Temporal BoneRadioGraphics, 2006
- Flat-Panel Volume Computed Tomography for Cochlear Implant Electrode Array Examination in Isolated Temporal Bone SpecimensOtology & Neurotology, 2006
- Vascular anomalies, sutures and small canals of the temporal bone on axial CTEuropean Journal of Radiology, 2005
- CT of the Normal Temporal Bone: Comparison of Multi– and Single–Detector Row CTRadiology, 2005
- High resolution computed tomography and magnetic resonance imaging in the pre-operative assessment of cochlear implant patientsThe Journal of Laryngology & Otology, 2003