Quality management of medical physics issues at the German heavy ion therapy project
Authors:
- Christian P. KargerCKChristian P. Karger
- Günther H. HartmannGHGünther H. Hartmann
- Oliver JäkelOJOliver Jäkel
- Peter HeegPHPeter Heeg
- 5 April 2000
- journal article
- Published by Wiley in Medical Physics
- Vol. 27 (4) , 725-736
Abstract
For the commissioning and operation of the German Heavy Ion Therapy Project a quality assurance program was developed and successfully applied. The complete radiotherapy process using heavy ions was carefully analyzed and divided into three areas related to beam delivery and control, safety‐interlock system and medical physics issues. In this paper, the medical physics issues are addressed. Since the irradiation with heavy ions is a nonstandard modality, new concepts and ion specific tests were developed. As far as possible, national and international standard specifications for radiotherapy were adopted. For each aspect, a performance characteristic and a corresponding acceptance test were introduced. In addition, test characteristics for the constancy tests were established. For all tests, intervention thresholds and test frequencies were specified. Using the described protocol of acceptance tests, the commissioning was passed successfully. The heavy ion irradiation facility was approved by the governmental authorities on the basis of these test results. During clinical operation, constancy tests are performed at the beginning of each treatment period, in order to maintain the quality found during the acceptance tests. Up to now, 48 patients have been treated within 6 treatment periods of 4 weeks each. The concepts used and the tests developed for the quality assurance program may serve as an example of how to introduce systematically a quality assurance program for a new treatment modality.Keywords
This publication has 13 references indexed in Scilit:
- A system for three-dimensional dosimetric verification of treatment plans in intensity-modulated radiotherapy with heavy ionsMedical Physics, 1999
- Erste Schwerionenbestrahlung von Patienten in Europa: Medizinphysikalische AspekteZeitschrift für Medizinische Physik, 1999
- Determination of water absorbed dose in a carbon ion beam using thimble ionization chambersPhysics in Medicine & Biology, 1999
- Schwerionentherapie bei der GSI: Erste Patienten behandelt !/„Existenzgründer aus Hochschulen”︁/Überkapazität an weicher Röntgenstrahlung?/Großbritannien: Ein „Wegeplan”︁ für die Teilchen- und Astrophysik/Luciano Maiani CERN-Generaldirektor ab 1999/BlickPhysikalische Blätter, 1998
- The 200‐MeV proton therapy project at the Paul Scherrer Institute: Conceptual design and practical realizationMedical Physics, 1995
- Calculation of Heavy Ion Inactivation Probabilities Based on Track Structure, X Ray Sensitivity and Target SizeRadiation Protection Dosimetry, 1994
- Comprehensive QA for radiation oncology: Report of AAPM Radiation Therapy Committee Task Group 40Medical Physics, 1994
- Magnetic scanning system for heavy ion therapyNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1993
- Computer systems and mechanical tools for stereotactically guided conformation therapy with linear acceleratorsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1992
- Stereotaxic localization of intracranial targetsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1987