Uni‐ and bipolar surface recording of human nerve responses
Authors:
- Lindsay F. HaasLHLindsay F. Haas
- 1 February 1991
- journal article
- research article
- Published by Wiley in Muscle & Nerve
- Vol. 14 (2) , 133-141
Abstract
Nerve conduction studies are of great clinical value in diagnosing nerve pathology and injury. In most neurophysiological laboratories nerve conduction recordings are routinely made with surface bipolar electrodes. More rarely, needle electrodes are used. A bipolarly recorded nerve action potential (NAP) is the difference between 2 unipolar NAPs recorded from each pole of a bipolar electrode and a remote reference. The delay between the 2 separated unipolar NAPs depends on the distance between the poles and the conduction velocity (CV). When the delay between the unipolar NAPs was increased (partly through simulation), the following changes of the bipolar NAP occurred: (1) total amplitude was maximal at a certain delay but decreased if the delay was shorter or longer, (2) latencies of the first positive and the first negative peaks increased slightly until their amplitudes reached maximal values, (3) a second negative peak of increasing latency appeared with longer delays, (4) latencies of later peaks increased linearly, and (5) total area increased nonlinearly. All parameters of the bipolarly recorded NAP (except the onset of the first positive phase) changed with increasing delay. The significance of this is that if NAPs are recorded with a bipolar electrode, standard values obtained for each nerve cannot be transferred between laboratories if different interelectrode (interpolar) distances are used. Furthermore, the assumption that a fixed interelectrode distance allows comparisons between reference values and patient data is incorrect.Keywords
This publication has 13 references indexed in Scilit:
- Far-field potentials recorded from action potentials and from a tripole in a hemicylindrical volumeElectroencephalography and Clinical Neurophysiology, 1989
- A model of the differing change in motor and sensory action potentials over distanceMuscle & Nerve, 1988
- Far‐field potentials from peripheral nerveNeurology, 1986
- Relation between size of compound sensory or muscle action potentials, and length of nerve segmentNeurology, 1986
- The distribution of conduction velocities (DCV) in peripheral nerves: A reviewMuscle & Nerve, 1984
- The effects of temperature on human compound action potentials.Journal of Neurology, Neurosurgery & Psychiatry, 1981
- Determinants of conduction velocity in myelinated nerve fibersMuscle & Nerve, 1980
- Nerve fiber conduction-velocity distributions. I. Estimation based on the single-fiber and compound action potentialsElectroencephalography and Clinical Neurophysiology, 1979
- Early recognition of nerve disorders by near‐nerve recording of sensory action potentialsMuscle & Nerve, 1978
- Evoked action potentials and conduction velocity in human sensory nervesBrain Research, 1966