Multiscale Texture Analysis: From18F-FDG PET Images to Histologic Images
Open Access
- 3 June 2016
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 57 (11) , 1823-1828
Abstract
Purpose: Characterizing tumor heterogeneity using texture indices (TI) calculated from Positron Emission Tomography (PET) images has shown promise in predicting treatment response or patient survival in some types of cancer. Yet, the relationship between PET-derived TI, precise tracer distribution and biological heterogeneity needs to be clarified. We investigated the relationship between PET-derived TI and observations made on autoradiography and histological slides. Methods: Three mice bearing orthopically implanted mammary tumors derived from transgenic MMTV-PyMT mouse were scanned with the Inveon PET/Computerized Tomograph after injection of 18F-FDG. Tumors were then sliced, autoradiography was performed and tumor slices were stained using haematoxylin and eosin. Six TI computed from PET, autoradiography and histological images were compared to assess the ability of texture analysis to capture heterogeneity at different scales. Results: TI were significantly correlated (Spearman coefficient R between 0.57 and 0.85) between PET and autoradiography images but the TI values differed in magnitude. The TI correlation was low between histological and PET or autoradiography images (R between 0.06 and 0.54). All TI were little or moderately influenced by the difference of voxel size and spatial resolution in autoradiography images. TI measured in autoradiography images were significantly different (pConclusion: Heterogeneity computed in vivo from PET images accurately reflects the heterogeneity of tracer uptake directly computed ex vivo from autoradiography images. Various tumor cell density and cell spatial distribution measured on pathology slides can be distinguished using TI calculated from autoradiography images despite the difference in voxel size and spatial resolution. Yet, tumor texture as assessed from PET images only coarsely reflects the spatial distribution and density of tumor cells.Keywords
This publication has 19 references indexed in Scilit:
- Textural analysis of pre-therapeutic [18F]-FET-PET and its correlation with tumor grade and patient survival in high-grade gliomasEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- The method and efficacy of support vector machine classifiers based on texture features and multi-resolution histogram from 18F-FDG PET-CT images for the evaluation of mediastinal lymph nodes in patients with lung cancerEuropean Journal of Radiology, 2015
- Tumor Heterogeneity-Based Resistance Guides Personalized Cancer MedicineFuture Oncology, 2014
- Texture analysis on 18F-FDG PET/CT images to differentiate malignant and benign bone and soft-tissue lesionsAnnals of Nuclear Medicine, 2014
- Relationship between Tumor Heterogeneity Measured on FDG-PET/CT and Pathological Prognostic Factors in Invasive Breast CancerPLOS ONE, 2014
- Computer-Aided Staging of Lymphoma Patients With FDG PET/CT Imaging Based on Textural InformationIEEE Journal of Biomedical and Health Informatics, 2013
- Three-dimensional positron emission tomography image texture analysis of esophageal squamous cell carcinomaNuclear Medicine Communications, 2013
- Intratumor Heterogeneity and Branched Evolution Revealed by Multiregion SequencingNew England Journal of Medicine, 2012
- Conventional and novel PET tracers for imaging in oncology in the era of molecular therapyCancer Treatment Reviews, 2008
- New, faster, image-based scatter correction for 3D PETIEEE Transactions on Nuclear Science, 2000