Comparison of the ACL and ACL graft forces before and after ACL reconstruction an in-vitro robotic investigation
Authors:
- Guoan LiGLGuoan Li
- Ramprasad PapannagariRPRamprasad Papannagari
- Louis E DefrateLDLouis E Defrate
- Jae Doo YooJYJae Doo Yoo
- Sang Eun ParkSPSang Eun Park
- Thomas J GillTGThomas J Gill
Open Access
- 1 January 2006
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (2) , 267-274
Abstract
Long-term follow-up studies have indicated that there is an increased incidence of arthrosis following anterior cruciate ligament (ACL) reconstruction, suggesting that the reconstruction may not reproduce intact ACL biomechanics. We studied not only the magnitude but also the orientation of the ACL and ACL graft forces. 10 knee specimens were tested on a robotic testing system with the ACL intact, deficient, and reconstructed (using a bone-patella tendon-bone graft). The magnitude and orientation of the ACL and ACL graft forces were determined under an anterior tibial load of 130 N at full extension, and 15, 30, 60, and 90 degrees of flexion. Orientation was described using elevation angle (the angle formed with the tibial plateau in the sagittal plane) and deviation angle (the angle formed with respect to the anteroposterior direction in the transverse plane). ACL reconstruction restored anterior tibial translation to within 2.6 mm of that of the intact knee under the 130-N anterior load. Average internal tibial rotation was reduced after ACL reconstruction at all flexion angles. The force vector of the ACL graft was significantly different from the ACL force vector. The average values of the elevation and deviation angles of the ACL graft forces were higher than that of the intact ACL at all flexion angles. Contemporary single bundle ACL reconstruction restores anterior tibial translation under anterior tibial load with different forces (both magnitude and orientation) in the graft compared to the intact ACL. Such graft function might alter knee kinematics in other degrees of freedom and could overly constrain the tibial rotation. An anatomic ACL reconstruction should reproduce the magnitude and orientation of the intact ACL force vector, so that the 6-degrees-of-freedom knee kinematics and joint reaction forces can be restored.Keywords
This publication has 27 references indexed in Scilit:
- High prevalence of knee osteoarthritis, pain, and functional limitations in female soccer players twelve years after anterior cruciate ligament injuryArthritis & Rheumatism, 2004
- The effect of tibiofemoral joint kinematics on patellofemoral contact pressures under simulated muscle loadsJournal of Orthopaedic Research, 2004
- Anterior Cruciate Ligament Reconstruction With Patellar Autograft TendonClinical Orthopaedics and Related Research, 2002
- Medial collateral ligament autografts have increased creep response for at least two years and early immobilization makes this worseJournal of Orthopaedic Research, 2002
- In situ forces in the anterior cruciate ligament and its bundles in response to anterior tibial loadsJournal of Orthopaedic Research, 1997
- Contact pressure and tension in anterior cruciate ligament grafts subjected to roof impingement during passive extensionJournal of Orthopaedic Research, 1997
- Effect of tension and placement of a prosthetic anterior cruciate ligament on the anteroposterior laxity of the kneeJournal of Orthopaedic Research, 1992
- Factors affecting the region of most isometric femoral attachmentsThe American Journal of Sports Medicine, 1989
- A biomechanical comparison of different surgical techniques of graft fixation in anterior cruciate ligament reconstructionThe American Journal of Sports Medicine, 1987
- Sensitivity of Insertion Locations on Length Patterns of Anterior Cruciate Ligament FibersJournal of Biomechanical Engineering, 1986