Detection of tympanic membrane movement using film patch with integrated strain gauge, assessed by optical coherence tomography: experimental study
Authors:
- T JustTJT Just
- T ZehlickeTZT Zehlicke
- O SpechtOSO Specht
- W SassWSW Sass
- C PunkeCPC Punke
- W SchmidtWSW Schmidt
- E LankenauELE Lankenau
- D BehrendDBD Behrend
- H W PauHPH W Pau
- 27 January 2011
- journal article
- research article
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 125 (5) , 467-473
Abstract
Objective: : We report an ex vivo and in vivo experimental study of a device designed to measure tympanic membrane movement under normal and pathological conditions, assessed using optical coherence tomography.Materials and methods: : We designed two types of flexible, round film patch with integrated strain gauge, to be attached to the tympanic membrane in order to measure tympanic membrane movement. Tympanic membrane attachment was assessed using optical coherence tomography. The devices were tested experimentally using an ex vivo model with varying middle-ear pressure.Results: : Optical coherence tomography reliably assessed attachment of the film patch to the tympanic membrane, before and after middle-ear pressure changes. Strain gauge voltage changes were directly proportional to middle-ear pressure recordings, for low pressure changes. Tympanic membrane perforations smaller than 2 mm could be sealed off with the film patch.Conclusion: : Attachment of the film patch with integrated strain gauge to the tympanic membrane was not ideal. Nevertheless, the strain gauge was able to precisely detect small pressure changes within the middle ear, in this experimental model.Keywords
This publication has 8 references indexed in Scilit:
- Evaluation of Eustachian tube function with perfect sequences: technical realization and first clinical results2009
- Intra-operative application of optical coherence tomography with an operating microscopeThe Journal of Laryngology & Otology, 2009
- Optical coherence tomography of the oval window nicheThe Journal of Laryngology & Otology, 2009
- Pressure changes in the human middle ear without opening the eustachian tubeActa Oto-Laryngologica, 2009
- Tensometrie – Konzept und erste Ergebnisse einer neuen Technik der Tubenfunktionsmessung über hochflexible DehnungsmessstreifenLaryngo-Rhino-Otologie, 2008
- Combining Optical Coherence Tomography (OCT) with an Operating Microscope2007
- Different Tympanometric Procedures Compared with Direct Pressure Measurements in Healthy EarsScandinavian Audiology, 1990
- Evaluation of noninvasive eustachian tube function tests in normal adultsThe Laryngoscope, 1988