Desynchronization: A Novel Model to Induce Heart Failure

Authors:
  • SVS. Voss
    S. Voss
  • HNH. Nef
    H. Nef
  • MLM. Lintz
    M. Lintz
  • COC. Oltenau
    C. Oltenau
  • SKS. Kostin
    S. Kostin
  • JSJ. Sperzel
    J. Sperzel
  • CTC. Troidl
    C. Troidl
  • WSW. Skwara
    W. Skwara
  • CHC. Hamm
    C. Hamm
  • AEA. Elsässer
    A. Elsässer

Abstract
Background: Previous large animal heart failure models led to inhomogeneous results. Therefore, we developed a novel model combining rapid pacing with forced ventricular desynchronization. Methods: Heart failure was induced in 20 pigs during a pacing period of 21 days. Group A (n = 10) received one right ventricular lead (220 bpm). In group B (n = 10), two leads were implanted in different right ventricular regions with beat-to-beat alternation of activation sites (each lead 110 bpm). Sham-operated pigs (n = 6) served as controls. Hemodynamics were invasively evaluated and tissue was analyzed by immunohistochemistry and zymography. Results: Hemodynamics were significantly more impaired in group B with an increase of pulmonary capillary wedge and central venous pressure and a reduction of cardiac index (control 4.3 ± 0.1 l/min/m2; A 3.6 ± 0.2; B 2.9 ± 0.2, p < 0.05). Heart-to-body weight ratio was significantly higher in group B. Histological analyses showed a significant increase of cell diameters and interstitial fibrosis with significantly higher collagen contents in group B. Conclusion: The new model with a combination of rapid pacing and forced desynchronization of the ventricular contraction is superior to traditional heart failure models induced solely by rapid pacing.