Multivariate optimization of a GC–MS method for determination of sixteen priority polycyclic aromatic hydrocarbons in environmental samples
Open Access
- 30 May 2008
- journal article
- research article
- Published by Wiley in Journal of Separation Science
- Vol. 31 (10) , 1787-1796
Abstract
This paper describes the development and optimization, by using multivariate analysis, of a GC–MS‐SIM method for evaluation of the 16 polyaromatic hydrocarbons considered as priority pollutants in atmospheric particulate material by the US EPA. In order to assure an adequate separation in the shortest analysis time, a multivariate design was used to set the conditions of the oven temperature program. The optimization process was carried out using factorial fractional design and Box–Behnken design. The following factors were evaluated: initial temperature, temperature rate #1, intermediary temperature, temperature rate #2, and final temperature. The optimized conditions were set at: 70°C (2 min) → 200°C (30°C/min, 5 min) → 300°C (5°C/min, 1.67 min). Moreover, we have also optimized the injector temperature as 310°C and sampling time as 0.8 min. The total analysis time was 33 min. Validation of GC–MS‐SIM yielded satisfactory results for repetitivity of the detector response and retention times, and linearity of calibration curves. LOD were established as 0.13–0.34 ng/mL (peak area) and 0.18–0.72 ng/mL (peak height). The method has been shown to be appropriate for the analysis of samples of atmospheric particulate material and/or other environmental matrices.Keywords
Funding Information
- CNPq, Brazil
- FAPESB, Brazil
- CAPES, Brazil
- FINEP, Brazil
- ANEEL, Brazil
- PRONEX, Brazil
- RECOMBIO, Brazil
This publication has 31 references indexed in Scilit:
- Box-Behnken design: An alternative for the optimization of analytical methodsAnalytica Chimica Acta, 2007
- Characterisation of polycyclic aromatic hydrocarbons in atmospheric aerosols by gas chromatography–mass spectrometryAnalytica Chimica Acta, 2007
- Polycyclic aromatic hydrocarbons from wood pyrolyis in charcoal production furnacesEnvironmental Research, 2006
- Health risk assessment on human exposed to environmental polycyclic aromatic hydrocarbons pollution sourcesScience of The Total Environment, 2006
- Electrochemical reduction potentials of 1-nitropyrene, 9-nitroanthracene, 6-nitrochrysene and 3-nitrofluoranthene and their correlation with direct-acting mutagenicitiesJournal of the Brazilian Chemical Society, 2005
- Multivariate optimisation of the experimental conditions for determination of three methylxanthines by reversed-phase high-performance liquid chromatographyTalanta, 2005
- Validação em métodos cromatográficos e eletroforéticosQuímica Nova, 2004
- Polycyclic Aromatic Hydrocarbons in the Atmosphere: Monitoring, Sources, Sinks and Fate. II: Sinks and FateAnnali di Chimica, 2004
- Rapid Quantitation of Ten Polycyclic Aromatic Hydrocarbons in Atmospheric Aerosols by Direct Hplc Separation After Ultrasonic Acetonitrile ExtractionInternational Journal of Environmental Analytical Chemistry, 1989
- Desorptivity Versus Chemical Reactivity of Polycyclic Aromatic Hydrocarbons (PAHs) in Atmospheric Aerosols Collected on Quartz Fiber FiltersInternational Journal of Environmental Analytical Chemistry, 1986