Improved in situ measurements of lead isotopes in silicate glasses by LA-MC-ICPMS using multiple ion counters
Authors:
- 8 January 2008
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 23 (4) , 535-543
Abstract
A new technique that improves the spatial resolution and quantification limits of the measurement of lead isotope ratios in silicate glasses with −1 total Pb by LA-MC-ICPMS is presented. The new method provides the capability of making quantitative, in situ lead isotope measurements on tiny objects of geologic interest such as mineral growth bands, melt inclusions, and accessory minerals, even where they are lead poor. The method allows for the concurrent, static measurement of 204Pb, 206Pb, 207Pb, 208Pb along with 202Hg in five Channeltron ion counters. Standard-sample-standard bracketing using USGS BCR2-G as the calibrant is used to correct for instrumental mass bias. Accuracy and precision of the method was evaluated by replicate analyses of various MPI-DING reference glasses with low lead concentrations (∼1–11 μg g−1) and well-determined isotopic ratios. Spot sizes for in situ analyses were as small as 40–69 μm, providing better spatial resolution than previous LA-MC-ICPMS results reporting 204Pb. Measured lead isotope ratios for the MPI-DING reference glasses T1-G (11.6 μg g−1 total Pb) and ATHO-G (5.67 μg g−1 total Pb) agree within 0.10% and 0.15% respectively of the preferred values using 40 μm spots. For MPI-DING KL2-G (2.07 μg g−1 total Pb) and ML3B-G (1.38 μg g−1 total Pb) measured lead ratios agree within 0.75% of the accepted values with typical precisions of 207Pb/206Pb and 208Pb/206Pb are within 0.45% of preferred values with precisions of <0.50% (2RSD). These results demonstrate improvement over previous LA-MC-ICPMS data in terms of both quantification limits and spatial resolution, while retaining similar levels of accuracy and precision.Keywords
This publication has 20 references indexed in Scilit:
- In situ petrographic thin section U–Pb dating of zircon, monazite, and titanite using laser ablation–MC–ICP-MSInternational Journal of Mass Spectrometry, 2006
- MPI‐DING reference glasses for in situ microanalysis: New reference values for element concentrations and isotope ratiosGeochemistry, Geophysics, Geosystems, 2006
- The Use of the Common Pb Isotope Composition of Detrital K-Feldspar Grains as a Provenance Tool and Its Application to Upper Carboniferous Paleodrainage, Northern EnglandJournal of Sedimentary Research, 2006
- LEAD ISOTOPE ANALYSIS OF ARCHAEOLOGICAL METALS BY MULTIPLE‐COLLECTOR INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY*Archaeometry, 2006
- MPI‐DING glasses: New geological reference materials for in situ Pb isotope analysisGeochemistry, Geophysics, Geosystems, 2005
- Improved in situ isotope analysis of low-Pb materials using LA-MC-ICP-MS with parallel ion counter and Faraday detectionJournal of Analytical Atomic Spectrometry, 2005
- Common-Pb corrected in situ U–Pb accessory mineral geochronology by LA-MC-ICP-MSJournal of Analytical Atomic Spectrometry, 2003
- Lead isotopic disequilibrium between sulfide and plagioclase in the bushveld complex and the chemical evolution of large layered intrusionsGeochimica et Cosmochimica Acta, 2003
- Precise and accurate in situ Pb-Pb dating of apatite, monazite, and sphene by laser ablation multiple-collector ICP-MSGeochimica et Cosmochimica Acta, 2002
- Precise elemental and isotope ratio determination by simultaneous solution nebulization and laser ablation-ICP-MS: application to U–Pb geochronologyChemical Geology, 2000