Accuracy and Precision of a Novel Photogate System to Measure Toe Clearance on Stairs
Authors:
- Timmion K. SkervinTSTimmion K. Skervin
- Neil M. ThomasNTNeil M. Thomas
- Andrew J. SchofieldASAndrew J. Schofield
- Mark A. HollandsMHMark A. Hollands
- Constantinos N. MaganarisCMConstantinos N. Maganaris
- Thomas D. O’brienTOThomas D. O’brien
- Vasilios BaltzopoulosVBVasilios Baltzopoulos
- Richard J. FosterRFRichard J. Foster
Open Access
Abstract
Background: Toe clearance on stairs is typically measured using optoelectronic systems, though these are often constrained to the laboratory, due to their complex setups. Here we measured stair toe clearance through a novel prototype photogate setup and compared this to optoelectronic measurements. Methods: Twelve participants (age 22 ± 3 years) completed 25 stair ascent trials, each on a seven-step staircase. Toe clearance over the fifth step edge was measured using Vicon and the photogates. Twenty-two photogates were created in rows through laser diodes and phototransistors. The height of the lowest photogate broken at step-edge crossing was used to determine photogate toe clearance. A limits of agreement analysis and Pearson’s correlation coefficient compared the accuracy, precision and relationship between systems. Results: We found a mean difference of −1.5 mm (accuracy) between the two measurement systems, with upper and lower limits (precision) of 10.7 mm and −13.8 mm, respectively. A strong positive correlation was also found (r = 70, n = 12, p = 0.009) between the systems. Discussion: The results suggest that photogates could be an option for measuring real-world stair toe clearances, where optoelectronic systems are not routinely used. Improvements to the design and measurement factors may help to improve the precision of the photogates.Keywords
Funding Information
- a Liverpool John Moores University (UK) PhD scholarship
This publication has 23 references indexed in Scilit:
- Analysis of foot clearance in firefighters during ascent and descent of stairsApplied Ergonomics, 2016
- Robust Foot Clearance Estimation Based on the Integration of Foot-Mounted IMU Acceleration DataSensors, 2015
- What You See Is What You Step: The Horizontal–Vertical Illusion Increases Toe Clearance in Older Adults During Stair AscentInvestigative Ophthalmology & Visual Science, 2015
- Selecting the number of trials in experimental biomechanics studiesInternational Biomechanics, 2015
- The detailed measurement of foot clearance by young adults during stair descentJournal of Biomechanics, 2013
- Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmologyOphthalmic and Physiological Optics, 2011
- Sample size calculation for an agreement studyPharmaceutical Statistics, 2010
- Agreement Between Methods of Measurement with Multiple Observations Per IndividualJournal of Biopharmaceutical Statistics, 2007
- Foot clearance during stair descent: effects of age and illuminationGait & Posture, 2005
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986