In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry
Author:
- 1 January 1993
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 31 (1) , 43-52
Abstract
The paper reports the results of investigations comparing the relative in vitro responses of different signal processing algorithms commonly employed in laser Doppler flowmetry (LDF). A versatile laser Doppler system is described which enabled complex signal processing to be implemented relatively simply using digital analysis. The flexibility of the system allowed a variety of processing algorithms to be studied by simply characterising the algorithm of interest under software control using a personal computer. An in vitro physical model is also presented which was used to maintain reproducible fluid flows. Flows of particles were studied in a physical model using both a near-infra-red (NIR) diode and an He/Ne laser source. The results show that frequency-weighted algorithms are responsive to both particle velocity and concentration, whereas non-weighted algorithms respond to concentration only. The linearity of the velocity response is critically dependent on both the dimensions of the in vitro model and the frequency bandwidth of the signalprocessing algorithm.Keywords
This publication has 12 references indexed in Scilit:
- In vivocomparison of a twin wavelength laser Doppler flowmeter using He—Ne and laser diode sourcesJournal of Medical Engineering & Technology, 1990
- A critical review of laser Doppler flowmetryJournal of Medical Engineering & Technology, 1990
- Depth discrimination in laser Doppler skin blood flow measurement using different lasersMedical & Biological Engineering & Computing, 1988
- Signal processor for laser Doppler tissue flowmetersMedical & Biological Engineering & Computing, 1984
- Laser‐Doppler Flowmetry—a Non‐invasive and Continuous Method for Blood Flow Evaluation in Microvascular StudiesActa Medica Scandinavica, 1984
- Model for laser Doppler measurements of blood flow in tissueApplied Optics, 1981
- Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood FlowIEEE Transactions on Biomedical Engineering, 1980
- Cutaneous Blood Flow Responses to Injection Trauma Measured by Laser Doppler VelocimetryJournal of Investigative Dermatology, 1980
- An Instrument to Measure Cutaneous Blood Flow Using the Doppler Shift of Laser LightIEEE Transactions on Biomedical Engineering, 1978
- LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD FLOWJournal of Investigative Dermatology, 1977