Evaluation of porous cup soil‐water samplers under controlled field conditions: comparison of ceramic and PTFE cups
Authors:
- 1 June 1992
- journal article
- Published by Wiley in European Journal of Soil Science
- Vol. 43 (2) , 261-271
Abstract
SUMMARY: The value of soil water samples used in ecological studies is highly dependent on the quality of the samplers. Tension soil‐water samplers are widely used to extract soil solutions, and the samplers are often tested in the laboratory under conditions that differ significantly from field conditions. This study describes a field procedure useful for comparison of two different tension soil‐water samplers. Ceramic and PTFE cups are compared. There were no differences in the concentrations sampled by the two different types of sampler for Na + , K + , Ca 2+ , Al 3+ , NH 4 + , H + and NPOC (non‐purgeable organic carbon). Change in the applied vacuum in the range 0 to –0.4 × 10 5 Pa did not change the concentrations of chemical species in the collected soil water. The ceramic cups collected significantly larger amounts of water due to differences in the hydrostatic characteristics of the two samplers. It was found that the ceramic samplers collected the highest concentrations of Mg 2+ in some situations. The results are evaluated and discussed in relation to the possible sources of errors and the temporal and spatial variabilities.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of porous ceramic cups for monitoring soil‐water aluminium in acid soils: comment on a paper by Raulund‐Rasmussen (1989)European Journal of Soil Science, 1990
- Review of soil solution samplersWater Resources Research, 1988
- POROUS CUP SAMPLERS; CLEANING PROCEDURES AND POTENTIAL SAMPLE BIAS FROM TRACE ELEMENT CONTAMINATIONSoil Science, 1988
- Chemistry of Tension Lysimeter Water and Lateral Flow in Spruce and Hardwood StandsJournal of Environmental Quality, 1987
- Patterns of acid deposition to a Danish spruce forestWater, Air, & Soil Pollution, 1986
- COMPARISON BETWEEN SUCTION AND FREE-DRAINAGE SOIL SOLUTION SAMPLERS1Soil Science, 1986
- PHOSPHORUS ADSORPTION IN VARIOUS SOIL-WATER EXTRACTION CUP MATERIALSSoil Science, 1984
- A MODIFIED VACUUM-PRESSURE LYSIMETER FOR SOIL WATER SAMPLINGSoil Science, 1982
- SOIL SOLUTION CONCENTRATIONS: EFFECT OF EXTRACTION TIME USING POROUS CERAMIC CUPS UNDER CONSTANT TENSION1Jawra Journal of the American Water Resources Association, 1976
- Preparation of Porous Ceramic Cups to be Used for Extraction of Soil Water Having Low Solute ConcentrationsSoil Science Society of America Journal, 1970