Enforcing Dependability and Timeliness in Controller Area Networks
- 1 November 2006
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 3755-3760
Abstract
Standard fieldbuses, such as the controller area network (CAN), are today a cost-effective solution for distributed computer control systems. However, the standard CAN protocol exhibits a set of severe shortcomings in respect to the provision of strict dependability and timeliness guarantees. This paper identifies those shortcomings and discusses the main design challenges we have been tackling in a comprehensive way to provide a CAN-based infrastructure support for extremely reliable hard real-time communications, dubbed CAN enhanced layer (CANELy)Keywords
This publication has 13 references indexed in Scilit:
- An analysable bus-guardian for event-triggered communication2004
- Probabilistic analysis of CAN with faults2003
- Schedulability analysis of an event-based real-time protocol framework2003
- A Columbus' egg idea for CAN media redundancy2003
- Fault-tolerant clock synchronization in CAN2002
- How hard is hard real-time communication on field-buses?2002
- Response time analysis under errors for CAN2002
- Integrating inaccessibility in response time analysis of CAN networks2000
- Scheduling messages on controller area network for real-time CIM applicationsIEEE Transactions on Robotics and Automation, 1997