Agreement between routinely used immunoassays for thyroid function testing in non‐pregnant and pregnant adults
Open Access
- 17 April 2024
- journal article
- research article
- Published by Wiley in Clinical Endocrinology
- Vol. 101 (1) , 69-77
Abstract
Objective: Thyroid function tests are common biochemical analyses, and agreement between the routinely used immunoassays is important for diagnosis and monitoring of thyroid disease. Efforts are continuously made to align the biochemical assays, and we aimed to evaluate the agreement between immunoassays used in a clinical laboratory setting among non‐pregnant and pregnant adults.Design: Cross‐sectional study.Participants: Serum samples were obtained from 192 blood donors (non‐pregnant adults) and from 86 pregnant women in the North Denmark Region with no known thyroid disease.Measurements: Each sample was used for measurement of thyroid‐stimulating hormone (TSH) with the routinely used automatic immunoassays in the regional Departments of Clinical Biochemistry (Alinity, Abbott Laboratories, Cobas, Roche Diagnostics, and Atellica, Siemens Healthineers) and reported as the median with 95% confidence interval (95% CI).Results: In nonpregnant adults, the level of TSH was higher with Cobas and Atellica than with Alinity as reflected by median (Alinity: 1.39 mIU/L (95% CI: 1.30–1.51 mIU/L); Cobas: 1.57 mIU/L (95% CI: 1.48–1.75 mIU/L); Atellica: 1.74 mIU/L (95% CI: 1.61–1.83 mIU/L)). Similarly, a trend was seen towards higher median TSH with Cobas than with Alinity among pregnant women (Alinity: 1.90 mIU/L (95% CI: 1.37–2.82 mIU/L); Cobas: 2.33 mIU/L (95% CI: 1.69–3.62 mIU/L)).Conclusion: Results of thyroid function tests obtained with different immunoassays were not interchangeable when evaluated among pregnant and non‐pregnant adults. The distinct differences are relevant for clinical decision making and emphasize the necessity of clinical laboratory information when different assays are used for diagnosis and monitoring of patients with thyroid disease.Keywords
This publication has 35 references indexed in Scilit:
- Large method differences for free thyroid hormone assays in the hyperthyroid range can affect assessment of hyperthyroid status: Comparison of Abbott Alinity to Roche Cobas, Siemens Centaur and equilibrium dialysis LC-MS/MSClinical Biochemistry, 2023
- Implementing reference systems for thyroid function tests – A collaborative effortClinica Chimica Acta, 2021
- Pregnancy Week-Specific Reference Ranges for Thyrotropin and Free Thyroxine in the North Denmark Region Pregnancy CohortThyroid®, 2019
- Childhood Thyroid Function Reference Ranges and Determinants: A Literature Overview and a Prospective Cohort StudyThyroid®, 2017
- HypothyroidismThe Lancet, 2017
- Hypothyroid Symptoms Fail to Predict Thyroid Insufficiency in Old People: A Population-Based Case-Control StudyThe American Journal of Medicine, 2016
- HyperthyroidismThe Lancet, 2016
- The U-Shaped Curve of Iodine Intake and Thyroid Disorders2009
- Free T4 immunoassays are flawed during pregnancyAmerican Journal of Obstetrics and Gynecology, 2009