Smartphone Applications (Apps) for Heart Rate Measurement in Children: Comparison with Electrocardiography Monitor
Authors:
- 21 November 2013
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 35 (4) , 726-731
Abstract
Heart rate (HR) measurement is essential for children with abnormal heart beats. The purpose of this study was to determine whether HR measurement by smartphone applications (apps) could be a feasible alternative to an electrocardiography (ECG) monitor. A total of 40 children, median age of 4.3 years, were studied. Using four free smartphone apps, pulse rates were measured at the finger (or toe) and earlobe, and compared with baseline HRs measured by ECG monitors. Significant correlations between measured pulse rates and baseline HRs were found. Both correlation and accuracy rate were higher in the earlobe group than the finger/toe group. When HR was <120 beats per min (bpm), the accuracy rates were not different between the two different measuring sites for each app (median of 65 vs 76 %). The accuracy rates in the finger/toe group were significantly lower than those in the earlobe group for all apps when HR was ≥120 bpm (27 vs 65 %). There were differences among apps in their abilities to measure pulse rates. Taking children’s pulse rate from the earlobe would be more accurate, especially for tachycardia. However, we do not recommend that smartphone apps should not be used for routine medical use or used as the sole form of HR measurement because the results of their accuracy are not good enough.Keywords
This publication has 12 references indexed in Scilit:
- Robust heart rate measurement with phonocardiogram by on-line template extraction and matching2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2011
- Investigating a smartphone imaging unit for photoplethysmographyPhysiological Measurement, 2010
- Extracorporeal life support for treatment of children with enterovirus 71 infection-related cardiopulmonary failureIntensive Care Medicine, 2009
- Enterovirus 71 in TaiwanPediatrics & Neonatology, 2008
- The Ear as an Alternative Site for a Pulse Oximeter Finger Clip SensorRespiratory Care, 2007
- Medium-term follow-up and modes of failure following epicardial pacemaker implantation in young children†EP Europace, 2007
- Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor TestAnesthesia & Analgesia, 2001
- Primary cardiac arrhythmias in childrenPediatric Emergency Care, 1999
- Non-invasive ambulatory blood pressure monitoring: technical possibilities and problems.1990
- Pulse Oximetry and Circulatory Kinetics Associated with Pulse Volume Amplitude Measured by Photoelectric PlethysmographyAnesthesia & Analgesia, 1986