Diffusive sensitivity to muscle architecture: a magnetic resonance diffusion tensor imaging study of the human calf
Authors:
- Craig J GalbánCGCraig J Galbán
- Craig J.CJCraig J.
- Stefan MaderwaldSMStefan Maderwald
- Kai UffmannKUKai Uffmann
- Armin de GreiffAGArmin de Greiff
- Mark E. LaddMLMark E. Ladd
- 20 August 2004
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 93 (3) , 253-262
Abstract
The aim of this study was to examine the diffusive properties of adjacent muscles at rest, and to determine the relationship between diffusive and architectural properties, which are task-specific to muscles. The principle, second, and third eigenvalues, trace of the diffusion tensor, and two anisotropic parameters, ellipsoid eccentricity (e) and fractional anisotropy (FA), of various muscles in the human calf were calculated by diffusion tensor imaging (DTI). Linear correlations of the calculated parameters to the muscle physiological cross-sectional area (PCSA), which is proportional to maximum muscle force, were performed to ascertain any linear relation between muscle architecture and diffusivity. Images of the left calf were acquired from six healthy male volunteers. Seven muscles were investigated in this study. These comprised the soleus, lateral gastrocnemius, medial gastrocnemius, posterior tibialis, anterior tibialis, extensor digitorum longus, and peroneus longus. All data were presented as the mean and standard error of the mean (SEM). In general, differences in diffusive parameter values occurred primarily between functionally different muscles. A strong correlation was also found between PCSA and the third eigenvalue, e, and FA. A mathematical derivation revealed a linear relationship between PCSA and the third eigenvalue as a result of their dependence on the average radius of all fibers within a single muscle. These findings demonstrated the ability of DTI to differentiate between functionally different muscles in the same region of the body on the basis of their diffusive properties.Keywords
This publication has 49 references indexed in Scilit:
- Analytical error propagation in diffusion anisotropy calculationsJournal of Magnetic Resonance Imaging, 2004
- Force‐length characteristics of the in vivo human gastrocnemius muscleClinical Anatomy, 2003
- Diffusion tensor MRI of myocardial fibers and sheets: Correspondence with visible cut‐face textureJournal of Magnetic Resonance Imaging, 2002
- Fiber tracking: principles and strategies – a technical reviewNMR in Biomedicine, 2002
- Diffusion‐tensor MRI: theory, experimental design and data analysis – a technical reviewNMR in Biomedicine, 2002
- Validation of diffusion tensor MRI‐based muscle fiber trackingMagnetic Resonance in Medicine, 2002
- Muscle function in critically ill patientsClinical Nutrition, 2001
- Diffusion tensor imaging: Concepts and applicationsJournal of Magnetic Resonance Imaging, 2001
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- Diffusional anisotropy is induced by subcellular barriers in skeletal muscleNMR in Biomedicine, 1999