Transcranial Motor Evoked Potentials during Basilar Artery Aneurysm Surgery: Technique Application for 30 Consecutive Patients
- 1 April 2004
- journal article
- case report
- Published by Wolters Kluwer Health in Neurosurgery
- Vol. 54 (4) , 916-924
Abstract
OBJECTIVE: Microsurgical clipping of basilar artery aneurysms carries a risk of neurological compromise resulting from midbrain or thalamic ischemia. Somatosensory evoked potential (SSEP) monitoring and electroencephalography are the standard techniques for assessing the level of cerebroprotective anesthesia and monitoring ischemia during temporary occlusion or after permanent clipping. Transcranial motor evoked potential (TcMEP) monitoring was added to determine whether this modality improved intraoperative monitoring. METHODS: Combined SSEP/electroencephalographic/TcMEP monitoring was used for 30 consecutive patients with basilar artery apex aneurysms in the past 1.5 years. Voltage thresholds were recorded before, during, and after aneurysm treatment for the last 10 patients. RESULTS: All 30 patients underwent an orbitozygomatic craniotomy for clipping (28 patients), wrapping (1 patient), or superficial temporal artery-superior cerebellar artery bypass (1 patient). Electrophysiological changes occurred for 10 patients (33%), elicited by temporary clipping (6 patients), permanent clipping (3 patients), or retraction (1 patient). Isolated SSEP changes were observed for one patient, isolated TcMEP changes for five patients, and changes in both TcMEPs and SSEPs for four patients. Among patients with simultaneous changes, TcMEP abnormalities were more robust and occurred earlier than SSEP abnormalities. Impaired motor conduction was detected first with an increase in the voltage threshold (from 206 ± 22 to 410 ± 49 V, P < 0.05, n = 3) and then with loss of TcMEP responses. SSEP and TcMEP signals returned to baseline values for all patients after corrective measures were taken. CONCLUSION: TcMEP monitoring can be safely and easily added to traditional neurophysiological monitoring during basilar artery aneurysm surgery. These results suggest that TcMEPs may be more sensitive than SSEPs to basilar artery and perforating artery ischemia. This additional intraoperative information might minimize the incidence of ischemic complications attributable to prolonged temporary occlusion or inadvertent perforator occlusion.Keywords
This publication has 28 references indexed in Scilit:
- “Threshold-level” multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoringJournal of Neurosurgery, 1998
- Somatosensory Evoked Potential Phase Reversal and Direct Motor Cortex Stimulation during Surgery in and around the Central RegionNeurosurgery, 1996
- Monitoring of Somatosensory Evoked Potentials during Surgery for Middle Cerebral Artery AneurysmsNeurosurgery, 1991
- Perforating branches of the basilar bifurcationJournal of Neurosurgery, 1990
- Evoked Potential Monitoring during Aneurysm Operation: Observations after Fifty CasesNeurosurgery, 1987
- Electrophysiological Monitoring during Basilar Aneurysm OperationNeurosurgery, 1987
- Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentialsAnnals of Neurology, 1986
- Comparison of the Effects of Ischaemia on Early Components of the Somatosensory Evoked Potential in Brainstem, Thalamus, and Cerebral CortexJournal of Cerebral Blood Flow & Metabolism, 1984
- Alteration of somatosensory evoked potentials in response to global ischemiaJournal of Neurosurgery, 1984
- Somatosensory Evoked Potentials in Experimental Brain Ischemia1984