A New Method for Electrical Impedance Tomography With Incomplete Electrode Array
- 14 August 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (18) , 21610-21619
Abstract
The possibility to design wearable devices based on Electrical Impedance Tomography (EIT) has recently given a boost to this technology. However, the coverage of the sensor array will vary with the size difference of the measured object, resulting in an incomplete measurement set. If this measurement set is directly invested in the solution of the inverse problem, the imaging quality will be significantly degraded. In this case, it is necessary to take measures to reduce the impact of missing measurement data on reconstruction. In this paper, a new method (MinR-DFF) is proposed which provides a novel solution to the problem of local measurement information loss due to incomplete electrode arrays and achieves high-quality image reconstruction. The effectiveness of the proposed method is verified by numerical simulation and solid-liquid two-phase experiment. By using this method, the correct images of the phantoms are successfully recovered with incomplete electrode array and both the correlation coefficients and the relative errors do not differ from the results using the complete measurement set by more than 5%.Keywords
Funding Information
- Fundamental Research Funds for the Central Universities (No. 3122019178)
This publication has 26 references indexed in Scilit:
- Rotational electrical impedance tomography using electrodes with limited surface coverage provides window for multimodal sensingMeasurement Science and Technology, 2018
- Joint inversion of lake-floor electrical resistivity tomography and boat-towed radio-magnetotelluric data illustrated on synthetic data and an application from the Äspö Hard Rock Laboratory site, SwedenGeophysical Journal International, 2017
- Practical Implementation of Electrical Tomography in a Distributed System to Examine the Condition of ObjectsIEEE Sensors Journal, 2017
- Estimating the sample mean and standard deviation from the sample size, median, range and/or interquartile rangeBMC Medical Research Methodology, 2014
- Electrical impedance tomography system based on active electrodesPhysiological Measurement, 2012
- Rotational electrical impedance tomographyMeasurement Science and Technology, 2007
- A portable bio-impedance system for monitoring lung resistivityMedical Engineering & Physics, 2006
- A new algorithm for identifying fuzzy measures and its application to pattern recognition2002
- Rank-Deficient and Discrete Ill-Posed Problems1998
- An Application of Electrocardiographic Lead Theory to Impedance PlethysmographyIEEE Transactions on Biomedical Engineering, 1971