Optimal load compensation by 3-phase 4-wire shunt active power filter under distorted mains supply employing bacterial foraging optimization
Authors:
- 1 December 2011
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 2325940X,p. 1-6
Abstract
Shunt active power filter (APF) has been proven as an effective method to overcome various power quality issues such as reactive power unbalance, unbalanced source currents and large harmonic and neutral currents resulted due to the proliferation of nonlinear loads. Optimizing the performance of APF using conventional mathematical modeling based linearized approaches is quite difficult because of the highly complex, nonlinear and non-stationary nature of power system networks that involve large number of inequality constraints. This paper proposes the implementation of Bacterial foraging optimization (BFO) to optimize the APF performance for load compensation under distorted supply voltage condition and sudden load fluctuation. Extensive MATLAB/Simulink based simulations were carried out and results demonstrate that the performance of BFO algorithm is superior compared to conventional approach in terms of both convergence rate and solution quality.Keywords
This publication has 11 references indexed in Scilit:
- PID controller design of nonlinear systems using an improved particle swarm optimization approachCommunications in Nonlinear Science and Numerical Simulation, 2010
- Control of a 3-phase 4-leg active power filter under non-ideal mains voltage conditionElectric Power Systems Research, 2008
- Instantaneous Power Theory and Applications to Power Conditioning2006
- Harmonic and reactive power compensation with shunt active power filter under non-ideal mains voltageElectric Power Systems Research, 2005
- A Hybrid Least Square-Fuzzy Bacterial Foraging Strategy for Harmonic EstimationIEEE Transactions on Evolutionary Computation, 2005
- A Particle Swarm Optimization Approach for Optimum Design of PID Controller in AVR SystemIEEE Transactions on Energy Conversion, 2004
- Active filtering of harmonic currents in three-phase, four-wire systems with three-phase and single-phase nonlinear loads2003
- A four-wire, current-controlled converter provides harmonic neutralization in three-phase, four-wire systems2002
- Biomimicry of bacterial foraging for distributed optimization and controlIEEE Control Systems, 2002
- Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage ComponentsIEEE Transactions on Industry Applications, 1984