Optical absorption of blood depends on temperature during a 0.5 ms laser pulse at 586 nm.

Authors:
  • TMT E Milner
    T E Milner
  • JBJ F Beek
    J F Beek
  • GLG W Lucassen
    G W Lucassen
  • MGM J Van Gemert
    M J Van Gemert

  • 1 March 1998
    • journal article
    • Vol. 67  (3) , 276-81
    • PMID:9523528
Abstract
Optical properties are important parameters in port wine stain laser treatment models. In this study we investigated whether changes in blood optical properties occur during a 0.5 ms laser pulse. Blood from three volunteers was irradiated in vitro with laser pulses (radiant exposure 2-12 J cm-2, wavelength 586 nm, pulse length 0.5 ms). Reflection and transmission coefficients, measured using double integrating spheres, decreased slightly during the first part of the pulse. At 2.9 J cm-2 radiant exposure, the reflectance increased, independent of total radiant exposure of the pulse. This was caused by blood coagulation. A second sudden increase in reflection and a significant increase in transmission occurred near 6.3 J cm-2 and was accompanied by a "popping" sound, indicating rapid expansion of bubbles due to blood vaporization. A multilayered model of blood was used to fit calculated transmission coefficient curves to the measurements and determine temperature-dependent optical blood absorption. Heat diffusion was shown to be of minor importance. A 2.5-fold increase in absorption for temperatures increasing from 20 to 100 degrees C, accurately describes transmission coefficients measured up to 2.9 J cm-2.