Intraoperative cone‐beam CT for correction of periaxial malrotation of the femoral shaft: A surface‐matching approach
Authors:
- Cari M. WhyneCWCari M. Whyne
- Michael DalyMDMichael Daly
- Douglas MoseleyDMDouglas Moseley
- Greg BootsmaGBGreg Bootsma
- Tomas SkrinskasTSTomas Skrinskas
- Jeffrey SiewerdsenJSJeffrey Siewerdsen
- David JaffrayDJDavid Jaffray
- 20 March 2007
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 34 (4) , 1380-1387
Abstract
Limb length, alignment and rotation can be difficult to determine in femoral shaft fractures. Shaft axis rotation is particularly difficult to assess intraoperatively. Femoral malpositioning can cause deformity, pain and secondary degenerative joint damage. The aim of this study is to develop an intraoperative method based on cone‐beam computed tomography (CBCT) to guide alignment of femoral shaft fractures. We hypothesize that bone surface matching can predict malrotation even with severe comminution. A cadaveric femur was imaged at 16 femoral periaxial malrotations ( to 60.1°). The images were processed resulting in an unwrapped bone surface plot consisting of a pattern of ridges and valleys. Fracture gaps were simulated by removing midline CT slices. The gaps were reconstituted by extrapolating the existing proximal and distal fragments to the midline of the fracture. The two bone surfaces were then shifted to align bony features. Periaxial malrotation was accurately assessed using surface matching (, slope 1.0). The largest mean error was 2.20° and the average difference between repeated measurements was 0.49°. CBCT can provide intraoperative high‐resolution images with a large field of view. This quality of imaging enables surface matching algorithms to be utilized even with large areas of comminution.Keywords
This publication has 35 references indexed in Scilit:
- 3D-imaging of the facial skeleton with an isocentric mobile C-arm system (Siremobil Iso-C3D)Dentomaxillofacial Radiology, 2003
- Cone‐beam volume CT breast imaging: Feasibility studyMedical Physics, 2002
- FEMUR FRACTURES CAUSED BY GUNSHOTS1993
- EDITORIAL COMMENT1993
- Computertomographische Torsionswinkel- und Längenmessung an der unteren ExtremitätRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1992
- Locked Intramedullary Nailing of Femoral Shaft Fractures1991
- The Huckstep Intramedullary Compression NailClinical Orthopaedics and Related Research, 1986
- Fractures of the Femoral Shaft in a Regional Hospital Setting1983
- Anatomy of the Femoral Neck and Head, with Comparative Data From Caucasians and Hong Kong ChineseClinical Orthopaedics and Related Research, 1980
- Closed Intramedullary Nailing for Ununited Femoral Shaft FracturesClinical Orthopaedics and Related Research, 1975