Comparison of spatial and temporal averaging on ultrafast imaging in presence of quantization errors
- 1 October 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
In compound plane wave imaging (CPWI), multiple plane waves are used to insonify the imaging region with different steering angles. The compounding operation is effectively a spatial averaging filter that reduces the speckles of the image and increases the image contrast and its lateral resolution. Although spatial averaging often improves CPWI image quality, quantization errors which dependent on sampling frequency and element spacing (pitch), introduced during beam steering reduce this improvement. In this study, the effect of spatial and temporal averaging on speckle noise reduction, contrast resolution and spatial resolution in ultrafast ultrasound imaging is evaluated. The overall results from the simulations shows that the maximum effect of quantization errors on speckle noise is 0.18 dB, on the image contrast is 0.27 dB, on axial resolution is 2.38% and finally on lateral resolution is 1.44%. On the other hand, plane wave imaging (PWI) employing temporal averaging technique which is not bound with quantization errors relatively produces high contrast to noise ratio (CNR) and speckle signal to noise ratio (SSNR) at 40 MHz for both centre frequency compared to CPWI.Keywords
This publication has 10 references indexed in Scilit:
- Thomson’s multitaper approach combined with coherent plane-wave compounding to reduce speckle in ultrasound imagingUltrasonics, 2015
- New performance metrics for ultrasound pulse compression systems2014
- Selecting the number and values of the CPWI steering angles and the effect of that on imaging quality2014
- Stolt's f-k migration for plane wave ultrasound imagingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2013
- Ultrasound array transmitter architecture with high timing resolution using embedded phase-locked loopsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2012
- Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastographyIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2009
- A new method of spatial compounding imagingUltrasonics, 2003
- Analysis of worst-case phase quantization sidelobes in focused beamformingIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- Delay Quantization Error in Phased Array ImagesIEEE Transactions on Sonics and Ultrasonics, 1981
- Phase Error Effects in Phased Array Beam Steering1977