Measurement and correction of respiration‐induced B0 variations in breast 1H MRS at 4 Tesla
Open Access
- 23 November 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (6) , 1239-1245
Abstract
Respiratory motion is well known to cause artifacts in magnetic resonance spectroscopy (MRS). In MRS of the breast, the dominant artifact is not due to motion of the breast itself, but rather it is produced by B0 field distortions associated with respiratory motion of tissues in the chest and abdomen. This susceptibility artifact has been reported to occur in the brain, but it is more apparent in the breast due to the anatomic proximity of the lungs. In the breast, these B0 distortions cause shot‐to‐shot frequency shifts, which vary an average of 24 Hz during a typical 1H MRS scan at 4 T. This variation can be corrected retrospectively by frequency shifting individual spectra prior to averaging. If not corrected, these shifts reduce spectral resolution and increase peak fitting errors. This work demonstrates the artifact, describes a method for correcting it, and evaluates its impact on quantitative spectroscopy. When the artifact is not corrected, quantification errors increase by an average of 28%, which dramatically impacts the ability to measure metabolite resonances at low signal‐to‐noise ratios. Magn Reson Med 52:1239–1245, 2004.Keywords
This publication has 23 references indexed in Scilit:
- Breathhold abdominal and thoracic proton MR spectroscopy at 3TMagnetic Resonance in Medicine, 2003
- Phase coherent averaging in magnetic resonance spectroscopy using interleaved navigator scans: Compensation of motion artifacts and magnetic field instabilitiesMagnetic Resonance in Medicine, 2002
- Motion correction and lipid suppression for1H magnetic resonance spectroscopyMagnetic Resonance in Medicine, 2000
- Methods and reproducibility of cardiac/respiratory double-triggered1H-MR spectroscopy of the human heartMagnetic Resonance in Medicine, 1999
- Effects of physiologic motion of the human brain upon quantitative1H-MRS: analysis and correction by retro-gatingNMR in Biomedicine, 1998
- Navigated single-voxel proton spectroscopy of the human liver.Magnetic Resonance in Medicine, 1998
- Localized proton MR spectroscopy of the human kidney in vivo by means of short echo time STEAM sequencesMagnetic Resonance in Medicine, 1994
- Motion Artifact Compensation in 1H Spectroscopic Imaging by Signal TrackingJournal of Magnetic Resonance, Series B, 1993
- Signal-to-Noise Improvement in in Vivo Spin-Echo Spectroscopy in the Presence of MotionJournal of Magnetic Resonance, Series B, 1993
- Motional degradation of metabolite signal strengths when using STEAM: A correction methodNMR in Biomedicine, 1992