High resolution imaging and quantification of the nailfold microvasculature using optical coherence tomography angiography (OCTA) and capillaroscopy: a preliminary study in healthy subjects
Authors:
Open Access
- 1 March 2022
- journal article
- research article
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 12 (3) , 1844-1858
Abstract
Background: A wide range of diseases, such as systemic sclerosis, can be diagnosed by imaging the nailfold microcirculation, which is conventionally performed using capillaroscopy. This study applied optical coherence tomography angiography (OCTA) as a novel high resolution imaging method for the qualitative and quantitative assessment of the nailfold microvasculature, and compared OCTA imaging with capillaroscopy. Methods: For qualitative assessment, high resolution OCTA imaging was used to achieve images that contained a wide field of view of the nailfold microvasculature through mosaic scanning. OCTA imaging was also used to observe the characteristic changes in the microvasculature under external compression of the upper arm. For quantitative evaluation, the capillary density and the capillary diameter of the nailfold microvasculature were assessed with both OCTA and capillaroscopy by repeated measurements over 2 days in 13 normal subjects. The results were analyzed using the intraclass correlation coefficient (ICC). Results: OCTA imaging showed the typical nailfold microvasculature pattern, part of which was not directly seen with the capillaroscopy. OCTA imaging revealed significant changes in the nailfold microvasculature when a large external pressure was applied via arm compression, but no significant changes were observed using capillaroscopy. The capillary density measured by OCTA and capillaroscopy was 6.8±1.5 and 7.0±1.2 loops/mm, respectively, which was not significantly different (P=0.51). However, the capillary diameter measured by OCTA was significantly larger than that measured using capillaroscopy (19.1±2.5 vs. 13.3±2.3 µm, PConclusions: This study demonstrated that OCTA is a potentially viable and reproducible tool for the imaging and quantification of the capillaries in the nailfold microvasculature. The results of this study provide a solid basis for future applications of OCTA in qualitative and quantitative assessment of nailfold microcirculation in vivo.Keywords
This publication has 43 references indexed in Scilit:
- Optical coherence tomography microangiography for monitoring the response of vascular perfusion to external pressure on human skin tissueJournal of Biomedical Optics, 2014
- Capillary blood flow imaging within human finger cuticle using optical microangiographyJournal of Biophotonics, 2013
- Microcirculation imaging based on full-range high-speed spectral domain correlation mapping optical coherence tomographyJournal of Biomedical Optics, 2013
- Motion-contrast laser speckle imaging of microcirculation within tissue bedsin vivoJournal of Biomedical Optics, 2013
- Accuracy evaluation of RBC velocity measurement in nail-fold capillariesMicrovascular Research, 2011
- In vivo volumetric imaging of microcirculation within human skin under psoriatic conditions using optical microangiographyLasers in Surgery and Medicine, 2011
- Comparison of laser Doppler imaging, fingertip lacticemy test, and nailfold capillaroscopy for assessment of digital microcirculation in systemic sclerosisArthritis Research & Therapy, 2010
- Micro computed tomography for vascular explorationJournal of Angiogenesis Research, 2010
- Nailfold video capillaroscopy in psoriasisBritish Journal of Dermatology, 2000
- INCREASED NAILFOLD CAPILLARY DIMENSIONS IN PRIMARY RAYNAUD'S PHENOMENON AND SYSTEMIC SCLEROSISRheumatology, 1995