Recent Developments in Multivariate Calibration
Authors:
- 1 December 2006
- journal article
- research article
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 36 (3-4) , 243-255
Abstract
This review covers the area of multivariate calibration; from pre-processing of data prior to modeling and applications of regression methods for calibration and prediction. The importance of pre-treatment of data is highlighted with many of the recently developed methods together with traditional methods. Several articles provide comparisons between different pre-processing methods. Methods for data from coupled chromatographic methods, which have found increasing use and where data pre-processing is a prerequisite for multivariate modeling, are also included. Many of the novel chemometric methods deal with model complexity and interpretation. A diverse set of applications are also presented and references are also given to early papers, making it possible to acquire a deeper knowledge of methods of interest.Keywords
This publication has 170 references indexed in Scilit:
- Characterization of different laser irradiation methods for quantitative Raman tablet assessmentJournal of Pharmaceutical and Biomedical Analysis, 2005
- Evaluation of basic algorithms for transferring quantitative multivariate calibrations between scanning grating and FT NIR spectrometersJournal of Pharmaceutical and Biomedical Analysis, 2005
- GC–MS libraries for the rapid identification of metabolites in complex biological samplesFEBS Letters, 2005
- Multivariate resolution of rank-deficient near-infrared spectroscopy data from the reaction of curing epoxy resins using the rank augmentation strategy and multivariate curve resolution alternating least squares approachAnalytica Chimica Acta, 2004
- Influence of data pre-processing on the quantitative determination of the ash content and lipids in roasted coffee by near infrared spectroscopyAnalytica Chimica Acta, 2004
- Averaged and weighted average partial least squaresAnalytica Chimica Acta, 2004
- Comparison of several curve resolution methods for drug impurity profiling using high-performance liquid chromatography with diode array detectionAnalytica Chimica Acta, 2003
- Enhanced NIR Calibration for Wort Fermentability Using Orthogonal Signal CorrectionJournal of the Institute of Brewing, 2003
- Development of robust calibration models in near infra-red spectrometric applicationsAnalytica Chimica Acta, 2000
- Extended multiplicative signal correction and spectral interference subtraction: New preprocessing methods for near infrared spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 1991