Use of portable partitions with high-efficiency particulate air filters in the endoscopy unit

Authors:

Abstract
Upper gastrointestinal endoscopy is one of the procedures with a high risk for spreading SARS-CoV-2 because the virus infects via aerosol transmission [1]. When Endoscopic procedures performed on patients infected with SARS-CoV-2 should be conducted in a negative-pressure room [2] [3]. Testing of SARS-CoV-2-positive patients may be routine because they are asymptomatic and a significant number of these individuals also exhibit gastrointestinal symptoms [2]. Several strategies have been suggested to reduce the risk of transmitting the infection during gastrointestinal endoscopy [4]. We have placed in our endoscopy units portable partitions with high-efficiency particulate air (HEPA) filters. The HEPA designation requires that a filter capture 99.97 % of particles ≥ 0.3 µm in size in that pass through it. Knowledge of HEPA filter functionality and prior Centers for Disease Control and Prevention (CDC) guidance for SARS-CoV-1 suggest the theoretical efficacy of HEPA filters for removing airborne SARS-CoV-2 [5]. To arrange the HEPA partitions properly, we evaluated the efficacy of placement by using CO2 generated from dry ice. Partitions with filters were placed on both sides of the endoscopy unit ([Fig. 1]). The partition placed near the patient’s back draws in air flowing over the patient, whereas the partition placed on the patient’s ventral side draws in air from the adjacent endoscopic unit and its output is filtered air. By adjusting the position of the partition and the operator, airflow can be directed toward the patient’s back ([Fig. 2] and [Video 1]). Combination devices with mechanical protection like the C-Cube [4] and a clean partition may be one countermeasure for ensuring the removal of aerosols containing SARS-CoV-2. Video 1 The efficacy of portable partitions. By adjusting the position of the partition and the operator, airflow can be directed toward the patient’s back. During the recording of this video, no air insufflation from the endoscope was used. Publication Date: 03 February 2021 (online) © 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany