Sequential/bead injection lab-on-valve incorporating a renewable microcolumn for co-precipitate preconcentration of cadmium coupled to hydride generation atomic fluorescence spectrometry
- 28 March 2006
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (5) , 535-538
Abstract
A sequential/bead injection lab-on-valve apparatus incorporating a renewable microcolumn packed with co-polymeric immobilized C18 microbeads was applied to the on-line co-precipitate separation/preconcentration of ultra-trace cadmium by hyphenating with hydride generation atomic fluorescence spectrometry. Cadmium was co-precipitated with lanthanum hydroxide and collected on a microcolumn in the lab-on-valve. The co-precipitate was eluted with hydrochloric acid and directed to meet tetrahydroborate and facilitate hydride generation. The hydride was separated from the reaction mixture and was swept into the atomizer. With a sampling volume of 500 μl, quantitative retention of cadmium was achieved, along with an enrichment factor of 9.8 and a sampling frequency of 11 h−1. A detection limit of 3.5 ng l−1 was derived, along with a RSD of 1.6% (0.1 μg l−1). The procedure was validated analyzing cadmium in certified reference materials.Keywords
This publication has 18 references indexed in Scilit:
- A hydride generation atomic fluorescence spectrometric procedure for selenium determination after flow injection on-line co-precipitate preconcentrationSpectrochimica Acta Part B: Atomic Spectroscopy, 2005
- Flow injection on-line solid phase extraction for ultra-trace lead screening with hydride generation atomic fluorescence spectrometryThe Analyst, 2005
- Octadecyl Immobilized Surface for Precipitate Collection with a Renewable Microcolumn in a Lab-on-Valve Coupled to an Electrothermal atomic Absorption Spectrometer for Ultratrace Cadmium DeterminationAnalytical Chemistry, 2005
- A low cost and sensitive procedure for lead screening in human whole blood with sequential injection-hydride generation-atomic fluorescence spectrometryJournal of Analytical Atomic Spectrometry, 2004
- Mild sample pretreatment procedures based on photolysis and sonolysis-promoted redox reactions as a new approach for determination of Se( iv ), Se( vi ) and Se( −II ) in model solutions by the hydride generation technique with atomic absorption and fluorescence detectionJournal of Analytical Atomic Spectrometry, 2004
- Simultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometryJournal of Analytical Atomic Spectrometry, 2004
- Effects of low-dose cadmium exposure on biological examinationsScience of The Total Environment, 2003
- Simultaneous Determination of Trace Cadmium and Arsenic in Biological Samples by Hydride Generation-Double Channel Atomic Fluorescence SpectrometryAnalytical Chemistry, 2002
- Urinary α1-Microglobulin, β2-Microglobulin, and Retinol-Binding Protein Levels in General Populations in Japan with References to Cadmium in Urine, Blood, and 24-Hour Food DuplicatesEnvironmental Research, 1995
- Biological monitoring of cadmium exposure in itai-itai disease epidemiologyInternational Archives of Occupational and Environmental Health, 1993