Study of Leakage Current Characteristics of High Voltage Insulators Ageing After Dry Season in Polluted Environmental Conditions
Authors:
- 5 October 2021
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 074-078
Abstract
This paper aims to study the leakage current characteristics of outdoor insulators exposed to pollution after a long dry season. This study observed the insulating phenomenon using the natural tropical climate of the Gowa Makassar region in Indonesia and the effect of NSDD, humidity, temperature, ultraviolet light, and rainfall in real-time. A microcontroller was used to collect data on leakage current and environmental-climate conditions over 23 months. Silicon rubber-type line posts and suspensions were used in the test sample, mounted on a 20 kV distribution network. The illustration of this test can represent actual conditions in the field. This leakage current test refers to the IEC 60060 standard with a real-time monitoring system for leakage current and tropical climatic conditions. For hydrophobic measurements using the spray method according to IEC 62073 and STRI 92/1 standards. The tests show that the leakage current and hydrophobic properties are influenced by changes in the tropical climate with temperature, humidity, ultraviolet radiation, and rainfall parameters. Changes in hydrophobic properties are also controlled by the mechanism for cleaning pollutants during rain and experiencing recovery when climatic conditions return to normal due to the hydrophobic transfer of contaminants. In addition, laboratory-based flashover mechanism testing was also carried out to determine the reliability of the insulator. This test demonstrates that the flashover voltage is affected by the number of pollutants and wetting on the silicone rubber polymer insulator's surface.Keywords
This publication has 7 references indexed in Scilit:
- Real-time monitoring of high voltage insulators in the tropical climatePRZEGLĄD ELEKTROTECHNICZNY, 2020
- Surface charge distribution analysis of polymeric insulator under AC and DC voltage based on numerical and experimental testsInternational Journal of Electrical Power & Energy Systems, 2019
- Leakage current characteristics study on electrical equivalent circuit of field-aged RTV silicone rubber coated and noncoated insulators in a coastal area2017
- Aging evaluation of silicone rubber insulators using leakage current and flashover voltage analysisIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- Effect of shape of insulator housings and positions of composite insulators on ageing resistance under high voltage and precipitationIEEE Transactions on Dielectrics and Electrical Insulation, 2012
- Characteristics of high voltage polymer insulator under accelerated artificial tropical climate multi stress aging2011
- Accelerated multistress aging of polymeric insulators under San Francisco coastal environment2002