The data treatment dependent variability of U–Pb zircon ages obtained using mono-collector, sector field, laser ablation ICPMS
- 2 February 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 27 (4) , 663-676
Abstract
U–Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U–Pb ages below 1 billion years (1 Ga), Pb206/U238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U–Pb zircon dating by sensitive sector field ICPMS.Keywords
This publication has 24 references indexed in Scilit:
- Data acquisition and calculation of U–Pb isotopic analyses using laser ablation (single collector) inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 2010
- Improved laser ablation U‐Pb zircon geochronology through robust downhole fractionation correctionGeochemistry, Geophysics, Geosystems, 2010
- Fundamental studies on the ablation behaviour of Pb/U in NIST 610 and zircon 91500 using laser ablation inductively coupled plasma mass spectrometry with respect to geochronologyJournal of Analytical Atomic Spectrometry, 2009
- Precise and accurate in situ U–Pb dating of zircon with high sample throughput by automated LA-SF-ICP-MSChemical Geology, 2009
- LA‐(MC)‐ICP‐MS Trends in 2006 and 2007 with Particular Emphasis on Measurement UncertaintiesGeostandards and Geoanalytical Research, 2008
- In situ petrographic thin section U–Pb dating of zircon, monazite, and titanite using laser ablation–MC–ICP-MSInternational Journal of Mass Spectrometry, 2006
- U‐Pb dating of zircon by LA‐ICP‐MSGeochemistry, Geophysics, Geosystems, 2006
- Zircon Crystal Morphology, Trace Element Signatures and Hf Isotope Composition as a Tool for Petrogenetic Modelling: Examples From Eastern Australian GranitoidsJournal of Petrology, 2005
- Chemical and phase composition of particles produced by laser ablation of silicate glass and zircon—implications for elemental fractionation during ICP-MS analysisJournal of Analytical Atomic Spectrometry, 2005
- The application of laser ablation-inductively coupled plasma-mass spectrometry to in situ U–Pb zircon geochronologyChemical Geology, 2004