Next Generation of Real Time Data Acquisition, Calibration and Control System for the RatCAP Scanner
Authors:
- Sachin S. JunnarkarSJSachin S. Junnarkar
- Jack FriedJFJack Fried
- Sudeepti SouthekalSSSudeepti Southekal
- Jean-Francois PratteJPJean-Francois Pratte
- Paul O'ConnorPOPaul O'Connor
- Veljko RadekaVRVeljko Radeka
- Paul VaskaPVPaul Vaska
- Martin PurschkeMPMartin Purschke
- Dardo TomasiDTDardo Tomasi
- Craig WoodyCWCraig Woody
- Réjean FontaineRFRéjean Fontaine
- 8 February 2008
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 55 (1) , 220-224
Abstract
RatCAP (Rat Conscious Animal PET) is miniature positron emission tomography scanner intended for neurological and behavioral study of small awake animal. The RatCAP system comprises of three distinct modules: rigid-flex technology based Printed Circuit Board (PCB) which houses the detector components and front end Application Specific Integrated Circuit (ASIC), Time to Digital Converter and Signal Processing module (TSPM) which receives and processes ASIC signals and transmits processed data over two Giga bit fiber optic links to PCI based data acquisition and control PCB (PACRAT). TSPM-3 is redesigned from previous versions to accommodate second generation front end ASIC and possible future two scanner expansion. ASIC's programmable features are exploited using new additional TSPM electronics for scanner calibration and test. Designs of these three modules and corresponding firmware and software upgrades are complete. Results from fully integrated next generation RatCAP on the bench are presented.Keywords
This publication has 8 references indexed in Scilit:
- An FPGA-Based, 12-Channel TDC And Digital Signal Processing Module For The RatCAP Scanner2006
- Digital Coincidence Processing for the RatCAP Conscious Rat Brain PET Scanner2006
- Development of a Simultaneous PET/MRI Scanner2005
- Front-end electronics for the RatCAP mobile animal PET scanner : timing discriminator and 32 line address priority serial encoder2005
- PDAQ - a fast data acquisition system for the RatCAP tomograph2005
- Design and performance of 0.18-/spl mu/m CMOS charge preamplifiers for APD-based PET scannersIEEE Transactions on Nuclear Science, 2004
- RatCAP: miniaturized head-mounted PET for conscious rodent brain imagingIEEE Transactions on Nuclear Science, 2004
- Front-end electronics for the RatCAP mobile animal PET scannerIEEE Transactions on Nuclear Science, 2004