Field Validation of a Novel Passive Sampler for Dissolved PFAS in Surface Waters
- 14 July 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
- Vol. 41 (10) , 2375-2385
Abstract
Numerous per- and polyfluoroalkyl substances (PFAS) are of growing concern worldwide due to their ubiquitous presence, bioaccumulation and adverse effects. Surface waters in the United States have displayed elevated concentrations of PFAS, but so far discrete water sampling has been the commonly applied sampling approach. In the present study we field-tested a novel integrative passive sampler, a microporous polyethylene tube, and derived sampling rates (Rs) for nine PFAS in surface waters. Three sampling campaigns were conducted, deploying polyethylene tube passive samplers in the effluent of two wastewater treatment plant (WWTP) effluents and across Narragansett Bay (Rhode Island, USA) for 1 month each in 2017 and 2018. Passive samplers exhibited linear uptake of PFAS in the WWTP effluents over 16–29 days, with in situ Rs for nine PFAS ranging from 10 ml day−1 (perfluoropentanoic acid) to 29 ml day−1 (perfluorooctanesulfonic acid). Similar sampling rates of 19 ± 4.8 ml day−1 were observed in estuarine field deployments. Applying these Rs values in a different WWTP effluent predicted dissolved PFAS concentrations mostly within 50% of their observations in daily composite water samples, except for perfluorobutanoic acid (where predictions from passive samplers were 3 times greater than measured values), perfluorononanoic acid (1.9 times), perfluorodecanoic acid (1.7 times), and perfluoropentanesulfonic acid (0.1 times). These results highlight the potential use of passive samplers as measurement and assessment tools of PFAS in dynamic aquatic environments. Environ Toxicol Chem 2022;41:2375–2385. © 2022 SETAC Abstract A novel integrative passive sampler was field-tested and sampling rates derived for nine per- and polyfluoroalkyl substances in two wastewater treatment plant effluents and in Narragansett Bay surface waters.Keywords
Funding Information
- National Institute of Environmental Health Sciences (P42ES027706)
- DOD SERDP (ER12-1280)
- RI STAC Program
- National Institute of Environmental Health Sciences (P42ES027706)
This publication has 45 references indexed in Scilit:
- Development and Calibration of a Passive Sampler for Perfluorinated Alkyl Carboxylates and Sulfonates in WaterEnvironmental Science & Technology, 2012
- Polyfluorinated Compounds: Past, Present, and FutureEnvironmental Science & Technology, 2011
- Development and Use of Polyethylene Passive Samplers To Detect Triclosans and Alkylphenols in an Urban EstuaryEnvironmental Science & Technology, 2011
- Distribution and sources of polyfluoroalkyl substances (PFAS) in the River Rhine watershedEnvironmental Pollution, 2010
- Perfluoroalkyl sulfonates and perfluorocarboxylates in two wastewater treatment facilities in Kentucky and GeorgiaWater Research, 2007
- Passive sampling techniques for monitoring pollutants in waterTrAC Trends in Analytical Chemistry, 2005
- A global survey of perfluorinated acids in oceansMarine Pollution Bulletin, 2005
- Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environmentsEnvironmental Toxicology and Chemistry, 2004
- Passive samplingTrAC Trends in Analytical Chemistry, 2002
- Perfluorinated Surfactants and the Environmental Implications of Their Use in Fire-Fighting FoamsEnvironmental Science & Technology, 2000