Magnetization and Giant Magnetoimpedance Effect of Co-Rich Microwires under Different Driven Currents
Open Access
- 13 December 2015
- journal article
- research article
- Published by Hindawi Limited in Journal of Sensors
- Vol. 2016, 1-6
Abstract
Co68.25Fe4.5Si12.25B15amorphous microwires with a diameter of 34 μm were prepared via the melt extraction method. The dependency of AC driving currentand frequency on giant magnetoimpedance (GMI) effect and magnetization were investigated using a 4294A impedance analyzer and the transverse Kerr effect. The GMI effect was analyzed whenchanged from 6 mA to 20 mA at a frequency ranging from 0.1 MHz to 15 MHz. The influence of AC current dependent on the frequency is correlated with the magnetization mechanism. The maximum transverse Kerr intensity (MTKI) decreased with the increase inunder direct magnetic field when the frequency was below megahertz. However, MTKI values were similar with the increase ofwhen it was over 2 MHz. Meanwhile, the GMI effect was optimized by selecting an adequate value of AC driving current, at which the circular permeability was higher when the frequency was not over 2 MHz. Results showed that the influence ofon magnetoimpedance became weak with strong skin effect and slightly stronger GMI effect driven by a higherwhen the frequency was between 2 MHz and 15 MHz. The skin effect turned out to be the key factor to the GMI effect; thus, there were no obvious differences in magnetization and GMI effect with AC driving current changing when the frequency was as high as 15 MHz.
Keywords
Funding Information
- Research Starting Funds for Imported Talents, Ningxia University, China (BQD2014019, ZR1411, 2014021018-4, 2013-Z06)
This publication has 17 references indexed in Scilit:
- Effect of wheel speed on the microstructure and nanohardness of rapidly solidified Ti–48Al–2Cr alloyMaterials Characterization, 2015
- Microstructure evolution in rapidly solidified Y added TiAl ribbonsIntermetallics, 2011
- Giant magnetoimpedance for biosensing: Advantages and shortcomingsJournal of Magnetism and Magnetic Materials, 2009
- Magnetoimpedance biosensor for Fe3O4 nanoparticle intracellular uptake evaluationApplied Physics Letters, 2007
- Microwire array for giant magneto-impedance detection of magnetic particles for biosensor prototypeJournal of Magnetism and Magnetic Materials, 2007
- Magnetic GMI sensor for detection of biomoleculesJournal of Magnetism and Magnetic Materials, 2005
- Influence of AC Magnetic Field Amplitude on the Surface Magnetoimpedance Tensor in Amorphous Wire With Helical Magnetic AnisotropyIEEE Transactions on Magnetics, 2004
- Magnetic Dynabeads® detection by sensitive element based on giant magnetoimpedanceBiosensors and Bioelectronics, 2004
- Effect of AC driving current on magneto-impedance effectSensors and Actuators A: Physical, 2000
- Giant magnetic field dependent impedance of amorphous FeCoSiB wireApplied Physics Letters, 1994