Internal Cardioverter Defibrillator Indications and Therapies after Atrial Baffle Procedure for d‐Transposition of the Great Arteries: A Multicenter Analysis
Authors:
- 23 September 2016
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 39 (10) , 1070-1076
Abstract
Background: Sudden cardiac death (SCD) is the most important cause of late mortality after atrial baffle procedure for d‐transposition of the great arteries (d‐TGA). Experience with internal cardioverter defibrillator (ICD) therapy in this population is limited. We conducted a multicenter cohort study to determine the current state of ICD therapy in individuals after atrial baffle procedure.Methods: Demographic and clinical data as well as data on device implantation, programming, ICD discharges, and complications after atrial baffle procedure for d‐TGA from four German centers were analyzed retrospectively.Results: ICD implantation was undertaken in 33 subjects. ICD implantation was undertaken as primary prevention in 29 (88%) and secondary prevention in four (12%) individuals. There were 21 (64%) subjects with atrial reentrant tachycardia (IART). During a median follow‐up of 4.8 years, seven appropriate ICD therapies were delivered in three (10%) individuals with primary prevention indication. No appropriate shocks were documented in subjects with secondary prevention indication. A total of 12 inappropriate ICD discharges occurred in eight (24%) individuals due to IART (n = 6) or lead failure (n = 2). ICD‐related complications were noted in seven individuals (21%): lead dislodgement/failure in five (15%) and ICD infection in two subjects (6%).Conclusions: The majority of individuals received an ICD for primary prevention of SCD, thus representing a liberal attitude of physicians for ICD implantation. During a median follow‐up of 4.8 years, the rate of appropriate ICD therapies was low and clearly exceeded by inappropriate ICD discharges. Lead failure and IART were present in >20% of the individuals and were frequent reasons for inappropriate ICD discharges. Facing these results, rigorous treatment of IART and careful ICD programming seems mandatory.Keywords
This publication has 15 references indexed in Scilit:
- 2012 ACCF/AHA/HRS Focused Update Incorporated Into the ACCF/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm AbnormalitiesJACC, 2013
- Implantable Cardioverter Defibrillator Therapy in Adults With Congenital Heart DiseaseCirculation: Arrhythmia and Electrophysiology, 2012
- Ventricular arrhythmias and sudden death in adults after a Mustard operation for transposition of the great arteriesEuropean Heart Journal, 2009
- Sudden Death and Defibrillators in Transposition of the Great Arteries With Intra-atrial BafflesCirculation: Arrhythmia and Electrophysiology, 2008
- Implantable Cardioverter-Defibrillators in Tetralogy of FallotCirculation, 2008
- Cardiac defibrillation therapy for at risk patients with systemic right ventricular dysfunction secondary to atrial redirection surgery for dextro-transposition of the great arteriesEP Europace, 2007
- Frequency and Causes of Implantable Cardioverter-Defibrillator Therapies: Is Device Therapy Proarrhythmic?The American Journal of Cardiology, 2006
- Predictors of sudden cardiac death after mustard or senning repair for transposition of the great arteriesJACC, 2004
- Long-term outcomes after the atrial switch for surgical correction of transposition: a meta-analysis comparing the Mustard and Senning proceduresCardiology in the Young, 2004
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002