Descending aortic dissection injured by tip of the sheath during transcatheter aortic valve implantation
- 25 February 2015
- journal article
- case report
- Published by Springer Nature in Cardiovascular Intervention and Therapeutics
- Vol. 31 (2) , 122-127
Abstract
An 86-year-old woman was referred for transcatheter aortic valve implantation (TAVI) because of recurrent severe aortic stenosis after balloon aortic valvuloplasty in May 2014. We planned to implant a 23-mm Sapien XT valve by transfemoral approach. During procedure, aortic dissection was detected by transesophageal echocardiography (TEE). The dissection limited to the descending aorta and did not include the ascending aorta. Therefore, our team decided to implant the 23-mm Sapien valve as planned. After the procedure, the dissection was treated conservatively without surgical repair. Three weeks later, she was discharged without any complications.Keywords
This publication has 10 references indexed in Scilit:
- 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart DiseaseCirculation, 2014
- Incidence and prognosis of vascular complications after transcatheter aortic valve implantationJournal of Vascular Surgery, 2013
- Management of Vascular Access in Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2013
- Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document (VARC-2)European Journal of Cardio-Thoracic Surgery, 2012
- Thoracic Endovascular Aortic Repair (TEVAR) for the treatment of aortic diseases: a position statement from the European Association for Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)European Heart Journal, 2012
- Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve ReplacementNew England Journal of Medicine, 2012
- Transfemoral Aortic Valve ImplantationJACC: Cardiovascular Interventions, 2011
- Iatrogenic dissection of the ascending aorta during TAVI sealed with the corevalve revalving prosthesisCatheterization and Cardiovascular Interventions, 2011
- Endovascular versus open repair for descending thoracic aortic rupture: institutional experience and meta-analysisEuropean Journal of Cardio-Thoracic Surgery, 2009
- The International Registry of Acute Aortic Dissection (IRAD)JAMA, 2000