Increased Anatomical Specificity of Neuromodulation via Modulated Focused Ultrasound
Open Access
- 4 February 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (2) , e86939
Abstract
Transcranial ultrasound can alter brain function transiently and nondestructively, offering a new tool to study brain function now and inform future therapies. Previous research on neuromodulation implemented pulsed low-frequency (250–700 kHz) ultrasound with spatial peak temporal average intensities (ISPTA) of 0.1–10 W/cm2. That work used transducers that either insonified relatively large volumes of mouse brain (several mL) with relatively low-frequency ultrasound and produced bilateral motor responses, or relatively small volumes of brain (on the order of 0.06 mL) with relatively high-frequency ultrasound that produced unilateral motor responses. This study seeks to increase anatomical specificity to neuromodulation with modulated focused ultrasound (mFU). Here, ‘modulated’ means modifying a focused 2-MHz carrier signal dynamically with a 500-kHz signal as in vibro-acoustography, thereby creating a low-frequency but small volume (approximately 0.015 mL) source of neuromodulation. Application of transcranial mFU to lightly anesthetized mice produced various motor movements with high spatial selectivity (on the order of 1 mm) that scaled with the temporal average ultrasound intensity. Alone, mFU and focused ultrasound (FUS) each induced motor activity, including unilateral motions, though anatomical location and type of motion varied. Future work should include larger animal models to determine the relative efficacy of mFU versus FUS. Other studies should determine the biophysical processes through which they act. Also of interest is exploration of the potential research and clinical applications for targeted, transcranial neuromodulation created by modulated focused ultrasound, especially mFU’s ability to produce compact sources of ultrasound at the very low frequencies (10–100s of Hertz) that are commensurate with the natural frequencies of the brain.Keywords
This publication has 24 references indexed in Scilit:
- Myo-Cortical Crossed Feedback Reorganizes Primate Motor Cortex OutputJournal of Neuroscience, 2013
- Potential intracranial applications of magnetic resonance–guided focused ultrasound surgeryJournal of Neurosurgery, 2013
- Focused ultrasound modulates region-specific brain activityNeuroImage, 2011
- Spectral Changes in Cortical Surface Potentials during Motor MovementThe Journal of Neuroscience, 2007
- Neural prosthesesThe Journal of Physiology, 2001
- Vibro-acoustography: An imaging modality based on ultrasound-stimulated acoustic emissionProceedings of the National Academy of Sciences, 1999
- Crossed corticothalamic and thalamocortical connections of macaque prefrontal cortexJournal of Comparative Neurology, 1987
- The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve StimulationIEEE Transactions on Biomedical Engineering, 1983
- Direct and indirect activation of nerve cells by electrical pulses applied extracellularly.The Journal of Physiology, 1976
- Excitation of pyramidal tract cells by intracortical microstimulation: effective extent of stimulating current.Journal of Neurophysiology, 1968