The Thermal Performance of Residential Electric Water Heaters Subjected to Various Off-Peak Schedules
Authors:
- 1 May 1996
- journal article
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 118 (2) , 73-80
Abstract
An increasing number of utilities control the supply of power to residential water heaters as one means of reducing peak electrical demand. Water heaters operated in this manner are referred to as off-peak water heaters. Several utilities are also considering the use of solar domestic water heaters as an additional means of limiting power demand during times of greatest electrical usage. The research described within this paper quantifies the variation in thermal efficiency attributable to subjecting residential electrical water heaters to various off-peak and water removal schedules and, thus, forms a basis of comparison to which the thermal efficiency of solar water heaters or other water heating technologies may be compared. Laboratory tests, where the off-peak period and hot water draw schedule were varied, were conducted on two residential storage water heaters. A computer model of an electric water heater was developed and validated. The laboratory tests and the model were used to quantify the effect that various off-peak and hot water draw schedules have on water heater thermal efficiency. Thermal efficiency was found to vary up to seven percent for water heaters which meet the present minimum efficiency standards as specified within the National Appliance Energy Conservation Act. The energy factor, as measured using the Department of Energy Test Procedure for Water Heaters, is shown to be independent of the off-peak schedule because of a “normalizing” that occurs as part of the calculation procedure.Keywords
This publication has 10 references indexed in Scilit:
- Analysis of water heater data from Athens load control experimentIEEE Transactions on Power Delivery, 1989
- The Application Of Peak Activated Rated A Technique To Load ManagementIEEE Transactions on Power Apparatus and Systems, 1985
- The Economics of Direct Control of Residential Loads on the Design and Operation of the Distribution System Part II Load CharacteristicsIEEE Transactions on Power Apparatus and Systems, 1983
- The Economics of Direct Control of Residential Loads on the Design and Operation of the Distribution System Part III The Economics of Load ManagementIEEE Transactions on Power Apparatus and Systems, 1983
- Load Management Implementation: Decisions, Opportunities and OperationIEEE Transactions on Power Apparatus and Systems, 1982
- Electric System Impacts of Storage Heating and Storage Water Heating - Part I of Two Parts (Background Information and Demonstration Description)IEEE Transactions on Power Apparatus and Systems, 1982
- Impacts of Several Major Load Management ProjectsIEEE Transactions on Power Apparatus and Systems, 1982
- Ten Years of Operating Experience with a Remote Controlled Water Heater Load Management System at Detroit EdisonIEEE Transactions on Power Apparatus and Systems, 1980
- Peak Shaving--A Way to Fight Rising CostsIEEE Transactions on Industry Applications, 1976
- Power/energy creative electric load management: New fools for the utilities include rate options, clock-actuated switches, radio control, and ripple control systemsIEEE Spectrum, 1975