Left ventricular assessment with artificial intelligence increases the diagnostic accuracy of stress echocardiography
Authors:
- Jamie M O’dRiscollJOJamie M O’dRiscoll
- William HawkesWHWilliam Hawkes
- Arian BeqiriABArian Beqiri
- Andrew ParkerAPAndrew Parker
- Ross UptonRURoss Upton
- William WoodwardWWWilliam Woodward
- Cameron DockerillCDCameron Dockerill
- Nikant SabharwalNSNikant Sabharwal
- Attila KardosAKAttila Kardos
- Daniel X AugustineDADaniel X Augustine
Open Access
- 21 September 2022
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 2 (5) , oeac059
Abstract
To evaluate whether left ventricular ejection fraction (LVEF) and global longitudinal strain (GLS), automatically calculated by artificial intelligence (AI), increases the diagnostic performance of stress echocardiography (SE) for coronary artery disease (CAD) detection. SEs from 512 participants who underwent a clinically indicated SE (with or without contrast) for the evaluation of CAD from seven hospitals in the UK and US were studied. Visual wall motion scoring (WMS) was performed to identify inducible ischaemia. In addition, SE images at rest and stress underwent AI contouring for automated calculation of AI-LVEF and AI-GLS (apical two and four chamber images only) with Ultromics EchoGo Core 1.0. Receiver operator characteristic curves and multivariable risk models were used to assess accuracy for identification of participants subsequently found to have CAD on angiography. Participants with significant CAD were more likely to have abnormal WMS, AI-LVEF, and AI-GLS values at rest and stress (all P < 0.001). The areas under the receiver operating characteristics for WMS index, AI-LVEF, and AI-GLS at peak stress were 0.92, 0.86, and 0.82, respectively, with cut-offs of 1.12, 64%, and −17.2%, respectively. Multivariable analysis demonstrated that addition of peak AI-LVEF or peak AI-GLS to WMS significantly improved model discrimination of CAD [C-statistic (bootstrapping 2.5th, 97.5th percentile)] from 0.78 (0.69–0.87) to 0.83 (0.74–0.91) or 0.84 (0.75–0.92), respectively. AI calculation of LVEF and GLS by contouring of contrast-enhanced and unenhanced SEs at rest and stress is feasible and independently improves the identification of obstructive CAD beyond conventional WMSI.Keywords
Funding Information
- NIHR HEE Healthcare Science Research (NIHR-HCS-P13–04-001)
This publication has 26 references indexed in Scilit:
- Two-Dimensional Speckle-Tracking during Dobutamine Stress Echocardiography in the Detection of Myocardial Ischemia in Patients with Suspected Coronary Artery DiseaseJournal of the American Society of Echocardiography, 2016
- Transient Ischemic Dilatation during Stress Echocardiography: An Additional Marker of Significant Myocardial IschemiaEchocardiography, 2016
- The value of core lab stress echocardiography interpretations: observations from the ISCHEMIA TrialCardiovascular Ultrasound, 2015
- Increase in end-systolic volume after exercise independently predicts mortality in patients with coronary heart disease: data from the Heart and Soul StudyEuropean Heart Journal, 2009
- Stress Echocardiography Expert Consensus Statement--Executive Summary: European Association of Echocardiography (EAE) (a registered branch of the ESC)European Heart Journal, 2008
- Optimal Medical Therapy with or without PCI for Stable Coronary DiseaseNew England Journal of Medicine, 2007
- Automated Analysis of Myocardial Deformation at Dobutamine Stress EchocardiographyJACC, 2007
- Transient Ischemic Left Ventricular Cavity Dilation Is a Significant Predictor of Severe and Extensive Coronary Artery Disease and Adverse Outcome in Patients Undergoing Stress EchocardiographyJournal of the American Society of Echocardiography, 2007
- Stress echocardiographyHeart, 2003
- The Subendocardium of the Left Ventricle, A Physiologic EnigmaChest, 1970