Improved Cochlear Implant Performance Estimation Using Tonotopic-Based Electrocochleography
Authors:
- 1 December 2023
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 149 (12) , 1120-1129
Abstract
Importance: Cochlear implantation produces remarkable results in postlingual deafness, although auditory outcomes vary. Electrocochleography (ECochG) has emerged as a valuable tool for assessing the cochlear-neural substrate and evaluating patient prognosis.Objective: To assess whether ECochG-total response (ECochG-TR) recorded at the best-frequency electrode (BF-ECochG-TR) correlates more strongly with speech perception performance than ECochG-TR measured at the round window (RW-ECochG-TR).Design, Setting, and Participants: This single-center cross-sectional study recruited 142 patients from July 1, 2021, to April 30, 2022, with 1-year follow-up. Exclusions included perilymph suctioning, crimped sound delivery tubes, non–native English speakers, inner ear malformations, nonpatent external auditory canals, or cochlear implantation revision surgery.Exposures: Cochlear implantation.Main Outcomes and Measures: Speech perception testing, including the consonant-nucleus-consonant (CNC) words test, AzBio sentences in quiet, and AzBio sentences in noise plus 10-dB signal to noise ratio (with low scores indicating poor performance and high scores indicating excellent performance on all tests), at 6 months postoperatively; and RW-ECochG-TR and BF-ECochG-TR (measured for 250, 500, 1000, and 2000 Hz).Results: A total of 109 of the 142 eligible postlingual adults (mean [SD] age, 68.7 [15.8] years; 67 [61.5%] male) were included in the study. Both BF-ECochG-TR and RW-ECochG-TR were correlated with 6-month CNC scores (BF-ECochG-TR: r = 0.74; 95% CI, 0.62-0.82; RW-ECochG-TR: r = 0.67; 95% CI, 0.54-0.76). A multivariate model incorporating age, duration of hearing loss, and angular insertion depth did not outperform BF-ECochG-TR or RW-ECochG-TR alone. The BF-ECochG-TR correlation with CNC scores was significantly stronger than the RW-ECochG-TR correlation (r difference = −0.18; 95% CI, −0.31 to −0.01; z = −2.02). More moderate correlations existed between 6-month AzBio scores in noise, Montreal Cognitive Assessment (MoCA) scores (r = 0.46; 95% CI, 0.29-0.60), and BF-ECochG-TR (r = 0.42; 95% CI, 0.22-0.58). MoCA and the interaction between BF-ECochG-TR and MoCA accounted for a substantial proportion of variability in AzBio scores in noise at 6 months (R2 = 0.50; 95% CI, 0.36-0.61).Conclusions and Relevance: In this case series, BF-ECochG-TR was identified as having a stronger correlation with cochlear implantation performance than RW-ECochG-TR, although both measures highlight the critical role of the cochlear-neural substrate on outcomes. Demographic, audiologic, and surgical factors demonstrated weak correlations with cochlear implantation performance, and performance in noise was found to require a robust cochlear-neural substrate (BF-ECochG-TR) as well as sufficient cognitive capacity (MoCA). Future cochlear implantation studies should consider these variables when assessing performance and related interventions.Keywords
This publication has 35 references indexed in Scilit:
- Round Window Electrocochleography Just Before Cochlear ImplantationOtology & Neurotology, 2014
- Factors Affecting Open-Set Word Recognition in Adults With Cochlear ImplantsEar & Hearing, 2013
- Intraoperative Round Window Recordings to Acoustic Stimuli From Cochlear Implant PatientsOtology & Neurotology, 2012
- Pre-, Per- and Postoperative Factors Affecting Performance of Postlinguistically Deaf Adults Using Cochlear Implants: A New Conceptual Model over TimePLOS ONE, 2012
- The Cochlear Implant: Historical Aspects and Future ProspectsThe Anatomical Record, 2012
- Electrocochleography during Cochlear Implantation for Hearing PreservationOtolaryngology–Head and Neck Surgery, 2012
- Development and Validation of the AzBio Sentence ListsEar & Hearing, 2012
- Verification of Computed Tomographic Estimates of Cochlear Implant Array PositionOtology & Neurotology, 2011
- The Montreal Cognitive Assessment, MoCA: A Brief Screening Tool For Mild Cognitive ImpairmentJournal of the American Geriatrics Society, 2005
- The origin of the low-frequency microphonic in the first cochlear turn of guinea-pigHearing Research, 1989